Home›Repair guides›Cummins/Onan›Storing the Genset

Cummins/Onan — Storing the Genset

Maintenance

From a Cummins/Onan owner's manual covering: 3.3 KY, 3.6 KY, 4.0 KY, 4KYFA26100, MicroLite 4000 Series, MicroLite 4000 Series KY. Check it applies to your exact model before use.

Applies to: Cummins/Onan 3.6 KY, Cummins/Onan 4.0 KY

Before you start

  • Gasoline preservatives (stabilizers) are toxic. Follow the instructions on the container label. Avoid skin contact.

Procedure

  1. Gasoline models only: fill the fuel tank with fresh fuel and add a fuel preservative (OnaFresh)
  2. Run the genset about 10 minutes at approximately 1/2 rated power
  3. Turn off large loads, push the line circuit breaker OFF and stop the genset
  4. Remove the air filter, restart the genset and spray an engine fogger (OnaGard) into the carburetor, then stop
  5. Change the air filter element if it is dirty
  6. Change the engine oil and attach a tag indicating its oil viscosity
  7. Disconnect the battery cables (negative cable first) and store the battery
  8. Plug the exhaust tail pipe to keep out dirt, moisture and bugs
  9. Close the fuel supply valve (if so equipped)

Specs & values

  • Store if genset will be idle for more than 120 days

Full service-parts list: Cummins/Onan 3.6 KY →, Cummins/Onan 4.0 KY →

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.