Cummins/Onan — Starting the Plant Manually
Operation · Genset
From a Cummins/Onan service manual covering: 10C, 10CW, 10CW-150R, 5CW, 5TW-0R, 6CW-54R, 7.5C, 7.5CW, 8CW. Check it applies to your exact model before use.
Applies to: Cummins/Onan 10CW, Cummins/Onan 10CW-150R
Before you start
- Do not spin engine or push downward on crank.
Procedure
- Adjust manual choke for temperature.
- Operate fuel pump primer 10 to 20 strokes if needed.
- Throw toggle switch to HAND CRANK.
- Engage starting crank.
- Crank with quick upward pull.
- Remove crank as soon as plant starts.
- Return toggle switch to ELECT START unless batteries disconnected.
Full service-parts list: Cummins/Onan 10CW →, Cummins/Onan 10CW-150R →
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.