Home›Repair guides›Cummins/Onan›Starting from Remote Location (Switch or Device) (Auto Mode)

Cummins/Onan — Starting from Remote Location (Switch or Device) (Auto Mode)

Operation · Control panel

From a Cummins/Onan operator's manual — check it applies to your exact model before use.

Applies to: Cummins/Onan DFE, Cummins/Onan DFEJ, Cummins/Onan DFEK, Cummins/Onan QSX15 engine

Procedure

  1. Place the 0/Manual/Auto switch in the Auto position.
  2. The genset can be started from a remote switch or device (e.g., transfer switch or PTC).
  3. Control completes Time Delay To Start (0 to 300 seconds).
  4. Emergency start is controlled by a remote contact between TB8-3 and TB8-5; open contact for emergency start.

Specs & values

  • Time Delay To Start 0 to 300 seconds
  • Time Delay To Stop 0 to 600 seconds

Full service-parts list: Cummins/Onan DFE →, Cummins/Onan DFEJ →, Cummins/Onan DFEK →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.