Home›Repair guides›Cummins/Onan›Starting at Set

Cummins/Onan — Starting at Set

Operation · Generator set

From a Cummins/Onan operator's manual covering: 5.0 MDKUB, 6.0 MDKUB, 7.5 MDKWB, 9.0 MDKWB. Check it applies to your exact model before use.

Applies to: Cummins/Onan 5.0 MDKUB, Cummins/Onan 6.0 MDKUB, Cummins/Onan 7.5 MDKWB, Cummins/Onan 9.0 MDKWB, Cummins/Onan MDKUB, Cummins/Onan MDKWB, Kubota Z482B engine, Kubota D722B engine

Before you start

  • Preheat longer than 30 seconds may damage glow plugs.
  • Excessive cranking can overheat starter.

Procedure

  1. Hold starting switch to STOP/PREHEAT for 10 to 30 seconds depending on temperature.
  2. Release switch, then move to START.
  3. Starter cranks and engine should start. Starter automatically disconnects when AC voltage builds.
  4. If engine does not start after 30 seconds cranking, release switch, wait two minutes, repeat preheat.
  5. If engine does not start on second try, check fuel supply and ensure fuel system primed.

Specs & values

Full service-parts list: Cummins/Onan 5.0 MDKUB →, Cummins/Onan 6.0 MDKUB →, Cummins/Onan 7.5 MDKWB →, Cummins/Onan 9.0 MDKWB →, Cummins/Onan MDKUB →, Cummins/Onan MDKWB →, Kubota Z482B engine →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →