Cummins/Onan — Starting at Control Panel (PCC)
Operation · PowerCommand Control 3100
From a Cummins/Onan owner's manual — check it applies to your exact model before use.
Applies to: Cummins/Onan DFE, Cummins/Onan KTA19 engine
Procedure
- Move Run/Off/Auto switch to the Run position.
- Starter begins cranking; after a few seconds engine starts and starter disconnects.
- If engine does not start, starter disengages and control indicates overcrank shutdown.
- To clear overcrank, place switch in Off and momentarily press Reset.
- Wait two minutes for starter to cool, then repeat starting procedure.
Specs & values
- Overcrank continuous cranking 75 seconds
- Cycle cranking 3, 4, or 5 cycles
Full service-parts list: Cummins/Onan DFE →
Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.