Home›Repair guides›Cummins/Onan›Setting GEN TYPE

Cummins/Onan — Setting GEN TYPE

Adjustments · EC-30 setup

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan HDKA, Cummins/Onan HDKB, Cummins/Onan HDKC

Before you start

  • GEN TYPE sets the service interval for service messages and critical automatic starting parameters.

Procedure

  1. Navigate to the SETUP & INFO display and press ENTER.
  2. Navigate to the SETUP GENSET display and press ENTER; the GEN TYPE is displayed.
  3. Press SET; the display will flash.
  4. Use the UP/DOWN key to select the GEN TYPE and press ENTER when the appropriate type is displayed.

Specs & values

  • GEN TYPE choices: NONE, QD 10/12, QD 6/8, QD 5.5, GAS/LP, GAS RV
  • Service In: QD 10/12 = 250 hours; QD 6/8 = 150 hours; QD 5.5 = 150 hours; GAS/LP = 150 hours; GAS RV = 150 hours
  • First service interval is 50 hours for all models

Full service-parts list: Cummins/Onan HDKA →, Cummins/Onan HDKB →, Cummins/Onan HDKC →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →