Home›Repair guides›Cummins/Onan›Raw Water Pump Priming

Cummins/Onan — Raw Water Pump Priming

Maintenance

From a Cummins/Onan operator's manual covering: 5.0 MDKUB, 6.0 MDKUB, 7.5 MDKWB, 9.0 MDKWB. Check it applies to your exact model before use.

Applies to: Cummins/Onan 5.0 MDKUB, Cummins/Onan 6.0 MDKUB, Cummins/Onan 7.5 MDKWB, Cummins/Onan 9.0 MDKWB, Cummins/Onan MDKUB, Cummins/Onan MDKWB, Kubota Z482B engine, Kubota D722B engine

Procedure

  1. Close sea cock.
  2. Remove hose from water filter outlet.
  3. Fill hose and pump with clean water.
  4. Replace hose and open sea cock.
  5. Check pump operation on start-up by observing water discharge from exhaust outlet.

Specs & values

  • Raw water flow at exhaust outlet should be about 3 gal/min (11.4 liter/min)

Full service-parts list: Cummins/Onan 5.0 MDKUB →, Cummins/Onan 6.0 MDKUB →, Cummins/Onan 7.5 MDKWB →, Cummins/Onan 9.0 MDKWB →, Cummins/Onan MDKUB →, Cummins/Onan MDKWB →, Kubota Z482B engine →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.