Cummins/Onan PX12000 / RGV13100 — GFCI Receptacle Test

Testing & diagnosis

For the Cummins/Onan PX12000 / RGV13100, from the Cummins/Onan service manual.

Applies to: Cummins/Onan PX12000, Yamaha EH65D engine, Cummins/Onan EH65D engine

Before you start

  • If the RESET button pops out during operation, stop the generator immediately and call a qualified electrician.

Procedure

  1. Push the blue TEST button; the red RESET button will pop out exposing TRIP.
  2. Power is off at the protected outlets, indicating the GFCI is functioning properly.
  3. If TRIP does not appear, do not use the generator; call a qualified electrician.
  4. Push RESET to restore power.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.