Cummins/Onan PX12000 / RGV13100 — 3-Phase Application Power Cable Connection
Installation · Output Terminals
For the Cummins/Onan PX12000 / RGV13100, from the Cummins/Onan service manual.
Applies to: Cummins/Onan PX12000, Yamaha EH65D engine, Cummins/Onan EH65D engine
Before you start
- Do not touch output terminals while the generator is running.
Procedure
- Shut down the generator before connecting or changing power cables.
- For three-phase 208V, insert the plug into receptacles X, Y, and Z.
- For single-phase 120V, insert the plug into W and X, W and Y, or W and Z.
- Maximum one-third of generator output can be utilized from each phase.
Specs & values
- Three-phase generator rated output: 10000VA
- Single-phase generator rated output: 3324VA (120V x 27.7A)
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.