Home›Repair guides›Cummins/Onan›3-Phase Application Power Cable Connection

Cummins/Onan PX12000 / RGV13100 — 3-Phase Application Power Cable Connection

Installation · Output Terminals

For the Cummins/Onan PX12000 / RGV13100, from the Cummins/Onan service manual.

Applies to: Cummins/Onan PX12000, Yamaha EH65D engine, Cummins/Onan EH65D engine

Before you start

  • Do not touch output terminals while the generator is running.

Procedure

  1. Shut down the generator before connecting or changing power cables.
  2. For three-phase 208V, insert the plug into receptacles X, Y, and Z.
  3. For single-phase 120V, insert the plug into W and X, W and Y, or W and Z.
  4. Maximum one-third of generator output can be utilized from each phase.

Specs & values

  • Three-phase generator rated output: 10000VA
  • Single-phase generator rated output: 3324VA (120V x 27.7A)

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.