Procedure

  1. Shut off fuel supply at tank and run unit until it stops.
  2. Fill fuel tank nearly full to lessen condensation.
  3. Drain oil while warm; replace drain plug and attach warning tag.
  4. Drain entire cooling system if no antifreeze/rust inhibitor is present.
  5. Pour two tablespoonfuls of rust inhibitor oil (SAE 50) into each cylinder and crank slowly by hand.
  6. Clean generator brushes, holders, commutator and collector rings with a clean cloth.
  7. Remove, clean and replace air cleaner; coat exposed parts with grease; plug exhaust outlet.
  8. Remove batteries or disconnect cables; provide a cover for the unit.