Home›Repair guides›Cummins/Onan›Returning Set to Service

Cummins/Onan PCC 2100 — Returning Set to Service

Maintenance · Generator set

For the Cummins/Onan PCC 2100, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan GGHE, Cummins/Onan GGHF, Cummins/Onan WSG-1068 engine

Procedure

  1. Remove protective cover.
  2. Remove exhaust plugs, seal from carburetor and PVC hose, and replace air cleaner.
  3. Check oil dipstick to make sure crankcase is full.
  4. Refill cooling system.
  5. Reconnect battery (positive cable first) and check specific gravity.
  6. Connect the battery charger (if applicable).
  7. Connect engine coolant heater to power supply (if applicable).
  8. Remove all loads before starting set.
  9. Start set and apply load of at least 50% of nameplate rating.
  10. Check all gauges for normal readings.

Specs & values

  • Apply load of at least 50% of nameplate rating.

Full service-parts list: Cummins/Onan GGHE →, Cummins/Onan GGHF →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →