Home›Repair guides›Cummins/Onan›Parallel Operation

Cummins/Onan — Parallel Operation

Installation · Parallel outlets

From a Cummins/Onan owner's manual covering: Onan P4500iDF, P4500iDF, P4500iDF Inverter. Check it applies to your exact model before use.

Applies to: Cummins/Onan P4500iDF, Cummins/Onan P4500iDF Inverter

Before you start

  • NEVER connect or disconnect the parallel cord leads when a generator is running.
  • DO NOT connect two red leads or two black leads into the same generator.
  • DO NOT use ECO MODE when in parallel operation.

Procedure

  1. Make sure both generator battery switches and ECO MODE switches are in the OFF position.
  2. Connect the black and red parallel cable leads to the black parallel ports; black lead to left port, red lead to right port.
  3. Connect the green ground lead to the ground terminal on each generator and tighten the nut.
  4. Start one generator and wait until the OUTPUT READY LED illuminates.
  5. Start the second generator and wait until its OUTPUT READY LED illuminates before connecting a load.
  6. Connect additional loads as described in the Power Management section.
  7. Unplug all loads before stopping the generators.

Specs & values

Full service-parts list: Cummins/Onan P4500iDF →, Cummins/Onan P4500iDF Inverter →

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.