Cummins/Onan — Overload Reset

Operation · Control panel

From a Cummins/Onan owner's manual covering: Onan P4500iDF, P4500iDF, P4500iDF Inverter. Check it applies to your exact model before use.

Applies to: Cummins/Onan P4500iDF, Cummins/Onan P4500iDF Inverter

Before you start

  • DO NOT overload the generator's capacity.

Procedure

  1. Turn off and unplug all connected electrical loads.
  2. Push the RESET button on the control panel until the OVERLOAD LED goes OFF and the OUTPUT READY LED is illuminated.
  3. Reset the circuit breakers if OFF.
  4. Verify that intended running and surge loads DO NOT exceed the generator capacity.
  5. Reconnect electrical loads sequentially, allowing the generator to stabilize after each load.