Operation · field rheostat

From a Cummins/Onan service manual covering: 10C, 10CW, 10CW-150R, 5CW, 5TW-0R, 6CW-54R, 7.5C, 7.5CW, 8CW. Check it applies to your exact model before use.

Applies to: Cummins/Onan 10CW, Cummins/Onan 10CW-150R

Procedure

  1. Turn the field rheostat to its maximum resistance position before starting.
  2. Start the plant.
  3. Connect the magnet by operating the magnet controller.
  4. Adjust the rheostat to give 250 volts, or the magnet rated voltage.
  5. Re-adjust the rheostat as the magnet warms up.

Specs & values

  • 250 volts

Full service-parts list: Cummins/Onan 10CW →, Cummins/Onan 10CW-150R →