Cummins/Onan — Lock-Off Pressure Test (Low-Pressure LPG Demand Regulator)

Testing & diagnosis

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan HGJAA, Cummins/Onan HGJAB, Cummins/Onan HGJAC, Cummins/Onan HGJAD, Cummins/Onan HGJAE, Cummins/Onan HGJAF

Before you start

  • Bench test: keep diaphragm in vertical plane to avoid erroneous readings

Procedure

  1. Connect regulator inlet to air pressure regulated to 11 in WC (28 cm).
  2. Disconnect hose from carburetor at regulator outlet.
  3. Tee two hoses to the regulator vent hose (3/8 in I.D.).
  4. Connect one hose to inclined manometer reading 0 to 2 in WC.
  5. Attach soap bubble to hose barb at regulator outlet.
  6. Blow lightly into pressurizing hose and read lock-off pressure.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Lock-off pressure 0.20 to 0.35 inches WC (5.1 to 8.9 mm)
  • Replace regulator if out of range

Full service-parts list: Cummins/Onan HGJAA →, Cummins/Onan HGJAB →, Cummins/Onan HGJAC →, Cummins/Onan HGJAD →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.