Cummins/Onan — Generator Set Removal
Installation
From a Cummins/Onan service manual — check it applies to your exact model before use.
Applies to: Cummins/Onan MDKC, Cummins/Onan MDKD
Before you start
- Fuel vapor fire/explosion hazard
- Heavy set can cause injury if dropped
Procedure
- Disconnect generator set negative (-) battery cable at the battery terminal.
- Disconnect generator set positive (+) battery cable from the wire harness.
- Disconnect the remote control plug wire from the generator set, if applicable.
- Disconnect generator load wires and tag for identification when reconnecting.
- Disconnect exhaust system and support brackets or hangers to allow set removal.
- Disconnect fuel line at the generator set housing and plug the fuel line end.
- Verify the generator set is adequately supported before loosening mounting bolts.
Full service-parts list: Cummins/Onan MDKC →, Cummins/Onan MDKD →
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.