Home›Repair guides›Cummins/Onan›Fuel Pump Control AC Voltage Conversion (240 VAC to 120 VAC)

Cummins/Onan — Fuel Pump Control AC Voltage Conversion (240 VAC to 120 VAC)

Installation · fuel transfer pump control

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan DFGB, Cummins/Onan DFGE, Cummins/Onan DFLB, Cummins/Onan DFLC, Cummins/Onan DFLE, Cummins/Onan VTA28-G5 engine, Cummins/Onan KTA50 engine

Before you start

  • Diesel fuel is highly combustible; installation must be performed by trained personnel per applicable codes

Procedure

  1. Remove jumpers between TB1-6 and TB1-7 in control box
  2. Connect jumper between TB1-5 and TB1-6, and another between TB1-7 and TB1-8
  3. Move selector switch S103 on control PCB to up position for 120V
  4. If equipped with transformer, remove jumpers between H2/H3 and connect H1-H3 and H2-H4
  5. Attach tag to control box indicating supply voltage

Full service-parts list: Cummins/Onan DFGB →, Cummins/Onan DFGE →, Cummins/Onan DFLB →, Cummins/Onan DFLC →, Cummins/Onan DFLE →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →