Home›Repair guides›Cummins/Onan›Field Coil Short Circuit Test

Cummins/Onan — Field Coil Short Circuit Test

Testing & diagnosis · field coils

From a Cummins/Onan service manual covering: 10C, 10CW, 10CW-150R, 5CW, 5TW-0R, 6CW-54R, 7.5C, 7.5CW, 8CW. Check it applies to your exact model before use.

Applies to: Cummins/Onan 10CW, Cummins/Onan 10CW-150R

Procedure

  1. Use a sensitive ohmmeter to test the resistance of each coil winding.
  2. If one coil reads more than 10% LESS than the average of the other three, it is short circuited.
  3. On electric cranking models, do not confuse the cranking winding with the shunt winding.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Coil reading more than 10% less than the average of the other three coils

Full service-parts list: Cummins/Onan 10CW →, Cummins/Onan 10CW-150R →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.