Home›Repair guides›Cummins/Onan›Cooling System Faucet/Heat Exchanger Cleaning

Cummins/Onan 4MCCK / 605MCCK — Cooling System Faucet/Heat Exchanger Cleaning

Maintenance

For the Cummins/Onan 4MCCK / 605MCCK, from the Cummins/Onan service manual.

Applies to: Cummins/Onan 605MCCK, Cummins/Onan MCCK, Cummins/Onan MCCK engine

Procedure

  1. Drain and fill the fresh water system with radiator cleaner.
  2. Always flush the cooling system to wash out deposits loosened by chemical cleaning.
  3. Remove the water outlet hose from the engine water jacket to the heat exchanger.
  4. Flush both the fresh water side and the raw water side of the heat exchanger.
  5. Remove the rubber impeller pump cover to flush the raw water side.
  6. Also flush the water-cooled exhaust manifold, then check the system thoroughly for leaks.

Full service-parts list: Cummins/Onan 605MCCK →, Cummins/Onan MCCK →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →