Cummins/Onan 12.5 RDJC / 15.0 RDJC — Normal Stop

Operation · Control panel

For the Cummins/Onan 12.5 RDJC / 15.0 RDJC, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan 12.5 RDJC, Cummins/Onan 15.0 RDJC, Cummins/Onan RDJC

Procedure

  1. Run the genset at no load for three to five minutes before stopping.
  2. Move the Run/Stop/Remote switch or remote starting switch to the STOP position.
  3. If the stop circuit fails, push the governor arm down to shut off the fuel injection pump.

Specs & values

  • Time delay stop adjustable from 0.5 to 15 minutes; approximately 3 to 5 minutes is recommended

Full service-parts list: Cummins/Onan RDJC →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.