Home›Repair guides›Cummins/Onan›Centrifugal Switch Adjustment

Cummins/Onan 12.5 RDJC / 15.0 RDJC — Centrifugal Switch Adjustment

Adjustments · Start-disconnect centrifugal switch

For the Cummins/Onan 12.5 RDJC / 15.0 RDJC, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan 12.5 RDJC, Cummins/Onan 15.0 RDJC, Cummins/Onan RDJC

Before you start

  • Shut down the set and disconnect the battery cable, negative (-) terminal first, before setting the breaker point gap

Procedure

  1. Locate the start-disconnect centrifugal switch on the side of the engine, above the oil filter.
  2. If necessary, loosen the stationary contact and adjust the point gap to 0.020 inch (51 mm).
  3. Replace burned or faulty points.

Specs & values

  • Point gap 0.020 in. (0.51 mm)
  • Switch closes when engine speed reaches 900 rpm and opens when the engine stops

Full service-parts list: Cummins/Onan RDJC →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →