Home›Repair guides›Caterpillar›Stopping the Engine (EMCP II and EMCP II+ Control Panels)

Caterpillar — Stopping the Engine (EMCP II and EMCP II+ Control Panels)

Operation

From a Caterpillar owner's manual covering: 3306B, 3406, 3406E, 3412C, SR4B. Check it applies to your exact model before use.

Applies to: Caterpillar 3306B, Caterpillar 3406, Caterpillar 3406E, Caterpillar 3412C, Caterpillar SR4B

Procedure

  1. Remove the load from the engine.
  2. To cool down at high idle and no load, turn the Engine Control Switch to the STOP position; it runs for the preset cool down time. If not desired, proceed to Step 3.
  3. Reduce the engine speed to low idle.
  4. While the engine is at low idle, measure the engine oil level between the ADD and FULL marks on the dipstick.
  5. Run the engine at low idle for approximately five minutes to allow the engine to cool down.
  6. Turn the Engine Control Switch to the Off/Reset position.

Specs & values

  • Low idle is approximately 66% of full load speed on 60 Hz units and approximately 80% on 50 Hz units

Full service-parts list: Caterpillar 3406 →, Caterpillar 3406E →, Caterpillar 3412C →, Caterpillar SR4B →

Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.