Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 264 kW |
| Standby kVA | 330 |
| Prime power | 240 kW |
| Controller | Microprocessor |
| Oil capacity | 28.0 L |
| Alternator | Leroy-Somer LSA 46.2 VL12 |
| Voltage options | 415/240 V, 400/230 V, 380/220 V, 240/120 V, 230/115 V, 220/110 V, 200/115 V |
| Phase | 3 |
| Rated current | 459 A |
| Power factor | 0.8 |
| Circuit breaker | 459 A |
| Battery group | 12 |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 41.0 L |
| Max ambient | 103 °C |
| Dimensions (L×W×H) | 4527×1410×2780 mm |
| Dry weight | 4519 kg |
| Sound level | 68.0 dBA @ 7 m |
| Fuel tank | 97.2 L |
Engine
| Oil capacity | 28.0 L |
|---|---|
| Coolant capacity | 41.0 L |
| Displacement | 9.36 L |
| Aspiration | Turbocharged, air-to-air charge cooled |
| Rated speed | 1500 rpm |
Same engine, other brands
2 brandsThe Volvo Penta TAD941GE in this set also powers 3 generator sets sold under 2 other brands. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.
| Brand | Models |
|---|---|
| Cukurova | CJ350VL, CJ350VM |
| Volvo Penta | TAD941GE |
Common questions
What is the power rating of the SDMO R330K?
The SDMO R330K is rated 264 kW standby (330.0 kVA).
Which engine powers the SDMO R330K?
The SDMO R330K is powered by the Volvo Penta TAD941GE engine.
Is the SDMO R330K diesel or gas?
The SDMO R330K runs on Diesel.
What is the oil capacity of the SDMO R330K?
The Volvo Penta TAD941GE engine in the SDMO R330K has an oil capacity of 28.0 liters.
What is the coolant capacity of the SDMO R330K?
The SDMO R330K cooling system holds 41 liters (10.8 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the SDMO R330K?
The SDMO R330K is rated 240 kW prime (300 kVA), against 264 kW standby.
What is the sound level of the SDMO R330K?
The SDMO R330K is rated at 68.0 dBA at 7 m, per the manufacturer specification sheet.
How much does the SDMO R330K weigh?
The SDMO R330K has a dry weight of 4519 kg (9962 lb).
What size fuel tank does the SDMO R330K have?
The SDMO R330K has a 97.2 liter (26 US gallon) fuel tank.
What voltage does the SDMO R330K produce?
The SDMO R330K is offered in 415/240 V, 400/230 V, 380/220 V, 240/120 V, 230/115 V, 220/110 V, 3-phase.
What battery does the SDMO R330K use?
The SDMO R330K uses 1 battery, 12 V each, group 12, per the manufacturer specification sheet.
What alternator does the SDMO R330K use?
The SDMO R330K uses a Leroy-Somer LSA 46.2 VL12 alternator.
Troubleshooting
1Fault codes
| Code | Meaning |
|---|---|
| Min/max alternator | Overspeed |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 100% | 74.4 | 19.7 |
| Standby | 110% | 82.2 | 21.7 |
Available documents
This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.