Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 1500 kW |
| Standby kVA | 1500 |
| Prime power | 1364 kW |
| Emissions | Tier I |
| Controller | Electronic Governor |
| Oil capacity | 11.5 L |
| Alternator | 501 VL10 |
| Voltage options | 480/277 V, 440/254 V, 220/127 V, 208/120 V |
| Phase | Three phase |
| Rated current | 153 A |
| Power factor | Not specified |
| Circuit breaker | 153 A |
| Battery group | Not specified |
| Battery voltage | Not specified V |
| Battery quantity | Not specified |
| Max ambient | Not specified °C |
| Tank runtime | Not specified hr |
Filters for the MTU 12V4000G81
1Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Fuel / water separator | P550849 | Fuel Filter, Water Separator Cartridge | NAPA 3763, BALDWIN PF7928, DAVCO 102526, DAVCO 102527 | FridayParts $20.90 KuduParts $39.00 |
Common questions
What is the power rating of the SDMO EXEL 2 X 1500 UC?
The SDMO EXEL 2 X 1500 UC is rated 1500 kW standby (1500.0 kVA).
Which engine powers the SDMO EXEL 2 X 1500 UC?
The SDMO EXEL 2 X 1500 UC is powered by the MTU 12V4000G81 engine.
Is the SDMO EXEL 2 X 1500 UC diesel or gas?
The SDMO EXEL 2 X 1500 UC runs on Diesel.
How much oil does the SDMO EXEL 2 X 1500 UC take?
The MTU 12V4000G81 engine in the SDMO EXEL 2 X 1500 UC has an oil capacity of 11.5 liters.
What is the continuous rating of the SDMO EXEL 2 X 1500 UC?
The SDMO EXEL 2 X 1500 UC is rated 1364 kW prime (1364 kVA), against 1500 kW standby.
What voltage does the SDMO EXEL 2 X 1500 UC produce?
The SDMO EXEL 2 X 1500 UC is offered in 480/277 V, 440/254 V, 220/127 V, 208/120 V, Three phase-phase.
What battery does the SDMO EXEL 2 X 1500 UC use?
The SDMO EXEL 2 X 1500 UC uses Not specified batteryies, Not specified V each, group Not specified, per the manufacturer specification sheet.
What alternator does the SDMO EXEL 2 X 1500 UC use?
The SDMO EXEL 2 X 1500 UC uses a 501 VL10 alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 75% | 34.5 | 12.2 |
Available documents
This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.