Home›Magnum›Magnum MMG130D Super Start

Magnum MMG130D Super Start Generator Set

The Magnum MMG130D Super Start is a 107 kW (134 kVA) standby generator set powered by a John Deere PE4045HFG93 engine. It is available at 120 V, 139 V, 208 V, 220 V, 240 V and 277 V, 3Ø, 60 Hz and rated 161 A. It holds about 15.5 L (4.1 gal) of oil and 29.8 L (7.9 gal) of coolant. Starting uses 1 group-24 battery rated 1000 CCA at 12 V. The set weighs about 2469 kg (5443 lb). An integrated tank holds 1295 L (342.1 gal), roughly 44 hours of runtime. The same PE4045HFG93 engine also powers generator sets from Generac and John Deere.

107 kW
Standby
4.5 L
Displacement
15.5 L
Oil capacity
0
Document types

Service parts for the MMG130D Super Start

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required
30561Air filtersee priceAmazon

Fuel system

1 required

Oil system

1 required
32912Oil filter$15.28eBay

Belts

1 required
33005Beltfind

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Frequency60.0 Hz
Standby power107 kW
Standby kVA134
Prime power98 kW
Oil capacity15.5 L
AlternatorMarathon 363PSL1607
Voltage options120 V, 139 V, 208 V, 220 V, 240 V, 277 V
Phase3Ø
Rated current161 A
Power factor1 (1Ø), 0.8 (3Ø)
Circuit breaker450 A
Battery group24
Battery cranking1000 CCA
Battery voltage12V V
Battery quantity1
Dry weight2469 kg
Fuel tank1295.0 L
Tank runtime44 hr

Engine

John Deere PE4045HFG93
Oil capacity31.2 L
Coolant capacity29.8 L
Displacement4.5 L
Aspirationturbocharged
Rated speed1800 rpm

Same engine, other brands

2 brands

The John Deere PE4045HFG93 in this set also powers 2 generator sets sold under 2 other brands. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.

BrandModels
GeneracMMG130
John DeereMMG130

Maintenance & consumables

for the John Deere PE4045HFG93
ItemSpecCapacityPart #Interval
Air filterpaper element30561 Amazon eBay
Fuel filter33024 Amazon eBay FridayParts $142.39
Oil filter32912 Amazon eBay $15.28
Battery—500 hr
Belt33005 KuduParts $27.00 FridayParts $27.09
Coolant—250 hr
Oil31.2—500 hr
Spark plug—250 hr

Common questions

What size generator is the Magnum MMG130D Super Start?

The Magnum MMG130D Super Start is rated 107 kW standby (134.0 kVA).

Which engine powers the Magnum MMG130D Super Start?

The Magnum MMG130D Super Start is powered by the John Deere PE4045HFG93 engine.

What is the oil capacity of the Magnum MMG130D Super Start?

The John Deere PE4045HFG93 engine in the Magnum MMG130D Super Start has an oil capacity of 31.2 liters.

What is the coolant capacity of the Magnum MMG130D Super Start?

The Magnum MMG130D Super Start cooling system holds 29.8 liters (7.9 US gallons) for the engine, per the manufacturer specification sheet.

What is the continuous rating of the Magnum MMG130D Super Start?

The Magnum MMG130D Super Start is rated 98 kW prime (122 kVA), against 107 kW standby.

What is the dry weight of the Magnum MMG130D Super Start?

The Magnum MMG130D Super Start has a dry weight of 2469 kg (5443 lb).

How big is the fuel tank on the Magnum MMG130D Super Start?

The Magnum MMG130D Super Start has a 1295 liter (342 US gallon) fuel tank, giving about 44 hours of runtime.

What voltage does the Magnum MMG130D Super Start produce?

The Magnum MMG130D Super Start is offered in 120 V, 139 V, 208 V, 220 V, 240 V, 277 V, 3Ø-phase.

What size battery does the Magnum MMG130D Super Start need?

The Magnum MMG130D Super Start uses 1 battery, 12V V each, 1000 CCA, group 24, per the manufacturer specification sheet.

Which alternator is fitted to the Magnum MMG130D Super Start?

The Magnum MMG130D Super Start uses a Marathon 363PSL1607 alternator.

Which oil filter part number does the Magnum MMG130D Super Start take?

The Magnum MMG130D Super Start uses oil filter part number 32912.

Which fuel filter part number does the Magnum MMG130D Super Start take?

The Magnum MMG130D Super Start uses fuel filter part number 33024.

What air filter does the Magnum MMG130D Super Start use?

The Magnum MMG130D Super Start uses air filter part number 30561.

Troubleshooting

42

Fault codes

CodeMeaning
SPN:100EngOil Press
SPN:102Boost Press
SPN:105Intake Temp
SPN:110EngCool Temp
SPN:175EngOil Temp
SPN:629Controller #1
SPN:636PositionSensor
SPN:637TimingSensor
SPN:651InjectorCyl#1
SPN:652InjectorCyl#2
SPN:653InjectorCyl#3
SPN:654InjectorCyl#4
SPN:655InjectorCyl#5
SPN:656InjectorCyl#6
SPN:677EngStartRelay
SPN:1485ECU MainRelay
SPN:3719.15High soot load caution
SPN:3719.16Very high soot load warning
SPN:3719.00Very high soot load - needs service
UbatBattery voltage is out of limits given by Batt Undervolt setpoints.

Symptoms & remedies

SymptomCauseRemedy
WrnMaintenance (Time to Service reminder displayed)Unit is due for maintenance or service (250 hour interval)Reset the running hours to 250: with the unit shut down, power up the controller with the Control On/Off toggle switch; press PAGE SELECT; press the down button to move the > cursor to Engine Protect; press ENTER; press ENTER again; press the up button and reset the current run time hour setting to 250; press ENTER to save; move the CONTROL ON/I toggle switch to the CONTROL OFF/O position
Low fuel level shutdownFuel level low (engine controller shuts the engine down when there is 5% of fuel remaining in the tank)Check the fuel level on the LCD window and confirm the generator is sitting level to ensure an accurate reading
Low fuel level shutdownLeaks in the fuel tankCheck for leaks in the fuel tank; the fuel tank should not run dry under normal circumstances
Low fuel level shutdownFuel level sender and connecting wiring damagedCheck the fuel level sender and the connecting wiring for damage; to check for continuity between the sender and the engine controller, remove the appropriate bolts from the control panel to access the inside of the control box and consult the DC wiring diagram for the proper path between the engine controller and the fuel level sender
Low oil pressure shutdownLow engine oil level (engine controller shuts the engine down when the oil pressure is less than 20 psi (138kPa))Check the level of the engine oil with the dipstick; add oil if required
Low oil pressure shutdownOil leaksVisually inspect the engine for oil leaks
Low oil pressure shutdownLoss of oil pressureIf the oil level is good, restart the unit and verify the loss of oil pressure; shut the engine down immediately if the oil pressure value does not read 5 psi (34kPa) within 5 seconds
Low oil pressure shutdownOil pressure senderCheck the oil pressure sender; to identify corrective action, refer to the troubleshooting section of the engine operator's manual provided with the unit
Low coolant level shutdownLow coolant levelAllow the engine to cool and confirm the unit is sitting level to ensure an accurate reading; check the coolant level in the radiator (remove the access panel from the top of the enclosure directly above the radiator to access the radiator cap) and add coolant until it is 3/4 in. (1.9 cm) below the filler neck; secure the radiator cap back into its original position
Low coolant level shutdownVisible leaksInspect coolant hoses, engine block and water pump for visible leaks
Low coolant level shutdownCoolant mixed with engine oilCheck the engine oil to verify no coolant has mixed with it (oil will appear milky if coolant is present); consult the engine operator's manual for additional information
High coolant temperature shutdownLow coolant level in the overflow jugCheck the coolant level in the overflow jug; allow the engine to cool, add coolant to the overflow jug if it is low and then check the level of coolant in the radiator (remove the access panel from the top of the enclosure directly above the radiator to access the radiator cap) and add coolant until it is 3/4 in. (1.9 cm) below the filler neck; secure the radiator cap back into its original position
High coolant temperature shutdownHigh coolant temperatureRestart the engine and read the coolant temperature to verify a high coolant temperature shutdown; stop the engine immediately if the coolant temperature is 230°F (110°C) or more
High coolant temperature shutdownRadiator shroud and ducting blockageCheck the radiator shroud and ducting for blockage and remove any foreign matter
High coolant temperature shutdownVisible leaksInspect coolant hoses, engine block and water pump for visible leaks
High coolant temperature shutdownSerpentine drive belt for the water pump tensionCheck the tension of the serpentine drive belt for the water pump
High coolant temperature shutdownEngine overheatingIf no other problems are found, remove the load on the generator and restart the engine; check the coolant temperature and shut the engine down immediately if it starts to overheat; consult the engine operator's manual for additional information on engine overheating
Overcrank shutdownFuel level in the tankCheck the fuel level in the tank
Overcrank shutdownImproper operation of the fuel pumpCheck for proper operation of the fuel pump
Overcrank shutdownAir filter blockageCheck the air filter for blockage
Overcrank shutdownEngine will not startIf the engine will not start, consult the engine operator's manual for additional information on troubleshooting starting problems
Overspeed or underspeed shutdownFrequency above or below 60.0 Hz (engine speed incorrect)Disconnect all loads and restart the generator; read the frequency (Hz) on the LCD display (with no loads on the generator, the frequency should read 60.0 Hz); if the frequency is above or below 60.0 Hz, the engine speed will have to be adjusted — refer to the engine operator's manual for throttle adjustments on mechanical governed units and see the electronic governor manual for electronically controlled units

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

3
Part #DescriptionQtySystem
P-130D-001Air Filter1Air filter Amazon eBay
P-175-002Oil Filter1Oil filter Amazon eBay
P-205-003Fuel Filter1Fuel filter Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime100%48.512.8
Standby100%28.07.4

Available documents

Full service, cheapest listings

Priced items from this model's own parts manual.

Oil filter 32912$15.28