Specifications
| Fuel | DIESEL FUEL |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 17 kW |
| Standby kVA | 17 |
| Prime power | 15 kW |
| Voltage options | 120 V, 240 V |
| Phase | single |
| Rated current | 142 A |
| Circuit breaker | 142 A |
| Dimensions (L×W×H) | 1800×890×950 mm |
| Dry weight | 577 kg |
| Sound level | 70.0 dBA @ 7 m |
| Fuel tank | 23.0 L |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | air filter | — | 500 hr | ||
| Fuel filter | fuel filter | — | 300 hr | ||
| Oil filter | engine oil filter | — | 100 hr | ||
| Battery | battery | — | |||
| Belt | — | ||||
| Coolant | automotive antifreeze coolant | — | |||
| Oil | engine oil | — | 100 hr | ||
| Spark plug | spark plug | — |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Common questions
What is the power rating of the Genmac HSD21?
The Genmac HSD21 is rated 17 kW standby (17.0 kVA).
What engine does the Genmac HSD21 use?
The Genmac HSD21 is powered by the Lombardini LDW 2004 engine.
What fuel does the Genmac HSD21 use?
The Genmac HSD21 runs on DIESEL FUEL.
Troubleshooting
4Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| Battery Supply Voltage (12 VDC) is not normal | 1. DC battery power not connected. Check for blown fuse. 2. Low battery voltage. 3. Wiring error. | |
| Speed trim value is abnormal | 1. Speed trim shorted or miswired. | |
| Gap between speed sensor and gear teeth is too great | 1. Gap between speed sensor and gear teeth too great. 2. Improper or defective wiring to the speed sensor. | Check gap. |
| Defective speed sensor | 3. Defective speed sensor |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 100% | 1.9 | 7.2 |
| Standby | 100% | 1.1 | 4.2 |