Home›Engines›Lombardini LDW 2004

Lombardini LDW 2004 Engine

The Lombardini LDW 2004 is a 2.07 L natural engine rated at 1800 rpm. It powers generator sets from Genmac, including the HSD21.

Also known as: LOMBARDINI LDW 2004

2.068 L
Displacement
1800 rpm
Rated speed

Engine specifications

Displacement2.068 L
Aspirationnatural
Rated speed1800 rpm

Generator sets powered by this engine

1

Common problems

9
  • Engine overspeed — Test 2: Manually hold the engine at the desired running speed, measure the DC voltage between terminals E(+) and H(-) on the speed control unit
    Cause: If the voltage reading is 1.0 to 1.5 VDC: speed adjustment set above desired speed; defective speed control unit
    Fix: Turn counterclockwise
  • Engine remains below desired speed — Test 1: measure the actuator output, terminals G & H, while running
    Cause: If voltage measurement is within 1.5 volts or more
  • Engine overspeed — Test 1: Do not crank, apply DC power to the governor system
    Cause: Actuator goes to full fuel
    Fix: Then disconnect speed sensor terminals C and D; if actuator still at full fuel — speed control unit defective; if actuator at minimum fuel position — erroneous speed signal, check speed sensor cable
  • Engine governing system does not function (system inoperative) — Step 4: terminals E(+) & H(-), normal reading 0.8-1.5 V while cranking
    Cause: Wiring error to actuator; defective speed control unit; defective actuator
  • Engine governing system does not function (system inoperative) — Step 3: terminals C(+) & D(-), normal reading 1.0 VAC RMS min. while cranking
    Cause: Gap between speed sensor and gear teeth too great; improper or defective wiring to the speed sensor; defective speed sensor
    Fix: Check gap; resistance between D & C should be 30 to 1200 Ω
  • Engine governing system does not function (system inoperative) — Step 2: terminals A(+) & B(-), normal reading 0-3.9 with speed trim, 7.1-7.9 without speed trim
    Cause: Speed trim shorted or miswired; defective unit
  • Engine governing system does not function (system inoperative) — Step 1: terminals E(+) & F(-), normal reading battery supply voltage (12 VDC)
    Cause: DC battery power not connected; blown fuse; low battery voltage; wiring error
  • Actuator does not energize fully while cranking — Test 2: momentarily connect terminal E to H; the actuator should move to the full fuel position
    Cause: Actuator or battery wiring in error; actuator or linkage binding; defective actuator
    Fix: Replace actuator
  • Actuator does not energize fully while cranking — Test 1: measure the DC voltage between terminals E(+) and H(-) on the speed control unit; should be 0.8 to 1.5 volts, if not
    Cause: Weak or undersized battery; actuator wiring incorrect; if voltage is greater than 1.5V, speed set too low
    Fix: Replace the battery if weak or undersized

Compiled from service & troubleshooting documentation across every generator set that uses the Lombardini LDW 2004.

Aftermarket parts that fit this engine

12
5840191 FridayParts $153.10 58401910 FridayParts $153.10 5840281 FridayParts $153.10 ED0058401910-S FridayParts $188.25 ED0011573600 FridayParts $388.99 ED0021752800-S Amazon eBay $22.90 FridayParts $19.99 KDW2204 FridayParts $111.50 ED0050100510S FridayParts $118.01 FP-XP-0002324 ED005100510-S FridayParts $162.88 ed005100510 FP-XP-0000440

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Also used in

1
  • Antonio Carraro HTM5600 — Tractor

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the displacement of the Lombardini LDW 2004?

The Lombardini LDW 2004 has a displacement of 2.068 liters.

Which generators use the Lombardini LDW 2004 engine?

The Lombardini LDW 2004 powers 1 generator set(s), including Genmac HSD21.

What is a common problem with the Lombardini LDW 2004 engine?

A commonly reported issue on generators using the Lombardini LDW 2004 is: Engine overspeed — Test 2: Manually hold the engine at the desired running speed, measure the DC voltage between terminals E(+) and H(-) on the speed control unit. Cause: If the voltage reading is 1.0 to 1.5 VDC: speed adjustment set above desired speed; defective speed control unit. Fix: Turn counterclockwise.