Specifications
| Fuel | DIESEL FUEL |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 12 kW |
| Standby kVA | 12 |
| Prime power | 10 kW |
| Voltage options | 120 V, 240 V |
| Phase | single |
| Rated current | 100 A |
| Circuit breaker | 100 A |
| Dimensions (L×W×H) | 1800×890×950 mm |
| Dry weight | 577 kg |
| Sound level | 66.7 dBA @ 7 m |
| Fuel tank | 23.0 L |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | air filter | — | 500 hr | ||
| Fuel filter | fuel filter | — | 300 hr | ||
| Oil filter | engine oil filter | — | 100 hr | ||
| Battery | battery | — | |||
| Belt | — | ||||
| Coolant | automotive antifreeze coolant | — | |||
| Oil | engine oil | — | 100 hr | ||
| Spark plug | spark plug | — |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Common questions
How many kW is the Genmac HSD17?
The Genmac HSD17 is rated 12 kW standby (12.0 kVA).
What engine is in the Genmac HSD17?
The Genmac HSD17 is powered by the Lombardini 12LD435-2 engine.
What fuel type does the Genmac HSD17 take?
The Genmac HSD17 runs on DIESEL FUEL.
Troubleshooting
4Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| Battery Supply Voltage (12 VDC) is not normal | 1. DC battery power not connected. Check for blown fuse. 2. Low battery voltage. 3. Wiring error. | |
| Speed trim value is abnormal | 1. Speed trim shorted or miswired. | |
| Gap between speed sensor and gear teeth is too great | 1. Gap between speed sensor and gear teeth too great. 2. Improper or defective wiring to the speed sensor. | Check gap. |
| Defective speed sensor | 3. Defective speed sensor |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 100% | 1.9 | 7.2 |
| Standby | 100% | 1.1 | 4.2 |