Service parts for the MLT4060DOTK
Grouped by system, with how many of each the parts manual calls for.
Fuel system
1 requiredOil system
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Frequency | 60.0 Hz |
|---|---|
| Standby power | 9.8 kW |
| Standby kVA | 13 |
| Prime power | 6 kW |
| Emissions | 4f |
| Oil capacity | 3.8 L |
| Alternator | Marathon 201CSA5411 (Class F insulation) |
| Voltage options | 120/240 V |
| Phase | single phase |
| Rated current | 50 A |
| Power factor | 1 (1Ø) |
| Circuit breaker | 30 A |
| Battery group | 24 |
| Battery cranking | 440 CCA |
| Battery voltage | 12V V |
| Battery quantity | 1 |
| Dimensions (L×W×H) | 170×68×70 mm |
| Dry weight | 770 kg |
| Sound level | 70.0 dBA |
| Fuel tank | 114.0 L |
| Tank runtime | 60 hr |
Engine
| Oil capacity | 5.1 L |
|---|---|
| Coolant capacity | 4.5 L |
| Displacement | 1.0 L |
| Aspiration | naturally aspirated |
| Rated speed | 1800 rpm |
Same engine, other brands
1 brandThe Kubota D1005-E3BG1-MGM-1 in this set also powers 1 generator set sold under 1 other brand. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.
| Brand | Models |
|---|---|
| Magnum | MLT3060 |
Maintenance & consumables
for the Kubota D1005-E3BG1-MGM-1| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Replace the air filter element yearly, or after six cleanings, whichever occurs first. | — | 365 hr | ||
| Fuel filter | 33192 | 500 hr | Amazon eBay $24.95 NAPA $27.99 | ||
| Oil filter | 7665025430 | 1000 hr | Amazon eBay $22.12 PartsGeek $7.98 NAPA $13.30 | ||
| Battery | Check the battery daily. | — | 24 hr | ||
| Belt | Replace Fan Belt | — | 1000 hr | ||
| Coolant | — | 24 hr | |||
| Oil | Change the engine oil and oil filter after the initial 50 hours of operation, then at the appropriate interval thereafter. | — | 1000 hr | ||
| Spark plug | Replace Air Filter Element | — | 1000 hr |
Compatible filters for the Kubota D1005-E3BG1-MGM-1 — cross-referenced via Donaldson. Options to verify against your serial number, not confirmed for this exact unit.
- Air filter: Kubota RG64842831 Kubota RG15842930 Kubota R141142289 Donaldson P628324 Donaldson P629467
Common questions
How many kW is the Generac MLT4060DOTK?
The Generac MLT4060DOTK is rated 9.8 kW standby (13.1 kVA).
What engine does the Generac MLT4060DOTK use?
The Generac MLT4060DOTK is powered by the Kubota D1005-E3BG1-MGM-1 engine.
What is the oil capacity of the Generac MLT4060DOTK?
The Kubota D1005-E3BG1-MGM-1 engine in the Generac MLT4060DOTK has an oil capacity of 5.1 liters.
What is the cooling system capacity of the Generac MLT4060DOTK?
The Generac MLT4060DOTK cooling system holds 4.5 liters (1.2 US gallons) for the engine, per the manufacturer specification sheet.
What is the prime power rating of the Generac MLT4060DOTK?
The Generac MLT4060DOTK is rated 6 kW prime (11 kVA), against 9.8 kW standby.
What is the sound level of the Generac MLT4060DOTK?
The Generac MLT4060DOTK is rated at 70.0 dBA, per the manufacturer specification sheet.
How much does the Generac MLT4060DOTK weigh?
The Generac MLT4060DOTK has a dry weight of 770 kg (1697 lb).
What size fuel tank does the Generac MLT4060DOTK have?
The Generac MLT4060DOTK has a 114 liter (30 US gallon) fuel tank, giving about 60 hours of runtime.
What voltages is the Generac MLT4060DOTK available in?
The Generac MLT4060DOTK is offered in 120/240 V, single phase-phase.
What size battery does the Generac MLT4060DOTK need?
The Generac MLT4060DOTK uses 1 battery, 12V V each, 440 CCA, group 24, per the manufacturer specification sheet.
What alternator does the Generac MLT4060DOTK use?
The Generac MLT4060DOTK uses a Marathon 201CSA5411 alternator. Insulation class F.
What oil filter does the Generac MLT4060DOTK use?
The Generac MLT4060DOTK uses oil filter part number 7665025430.
Which fuel filter part number does the Generac MLT4060DOTK take?
The Generac MLT4060DOTK uses fuel filter part number 33192.
Which air filter part number does the Generac MLT4060DOTK take?
The Generac MLT4060DOTK uses air filter part numbers KUBOTA RG64842831, KUBOTA RG15842930.
Troubleshooting
21Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| Low oil pressure shutdown | Low oil level | Verify oil level on dipstick. Add oil, if needed. |
| Low oil pressure shutdown | Oil leaking from engine | Visually inspect the engine for leaks. |
| Low oil pressure shutdown | Oil pressure switch failure | Refer to OEM engine operator's manual to identify corrective action. |
| High coolant temperature shutdown | Low coolant level | Add coolant if needed. Allow engine to cool, then check coolant level in radiator. Restart engine and check coolant temperature. Stop engine immediately if coolant temperature is 210°F (99°C) or more. |
| High coolant temperature shutdown | Blockage in radiator | Inspect radiator shroud and ducting for blockage and remove any foreign matter. |
| High coolant temperature shutdown | Leakage in coolant hoses, engine block, or water pump | Inspect for visible leaks. Verify tension of water pump serpentine drive belt. |
| Unit cranks, but will not start | Fuel level low | Check fuel level in tank. Verify fuel pump operation. |
| Unit cranks, but will not start | Restricted air filter | Inspect air filter for blockage. Refer to OEM engine operator's manual for additional information. |
| Mast Lights Off, but Ballast Indicators on Control Panel are On. | Light fixture is too hot. | Allow light to cool 10-15 minutes before restarting. |
| Mast Lights Off, but Ballast Indicators on Control Panel are On. | Faulty lamp connection. | Check that the lamp is tight in the socket. |
| Mast Lights Off, but Ballast Indicators on Control Panel are On. | Lamp broken | Check for broken arc tube or outer lamp jacket, broken or loose components in lamp envelope, or blackening/deposits inside tube. |
| Mast Lights Off, but Ballast Indicators on Control Panel are On. | Loose lighting connections | Check the connections inside the mast junction box and each mast light housing/socket. |
| Mast Lights Off, but Ballast Indicators on Control Panel are On. | Damaged or loose electrical cord | Check the mast electrical cord for damage and check the cord connections inside the control box. |
| Mast Lights Off, and Ballast Indicators on the Control Panel are Off. | Loose lighting connections | Check the connections inside the control box and inside each ballast box. |
| Mast Lights Off, and Ballast Indicators on the Control Panel are Off. | Generator output incorrect. | Check the incoming voltage to the ballast by checking the available voltage on the GFCI receptacle. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, the engine speed may need to be adjusted or generator may require service. |
| Mast Lights Off, and Ballast Indicators on the Control Panel are Off. | Low transformer output. | The voltage from the transformer should read approximately 400VAC as the light "strikes" (induces an arc), then drop and slowly rise back up to stabilize at 240-260VAC. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced. |
| Mast Lights On But the Light Output is Low | Fixture and/or lens is dirty. | Clean reflective surface inside fixture and both inside and outside surface of glass lens. Use mild soap and water to clean lens. Other chemicals may have an adverse effect on the glass. |
| Mast Lights On But the Light Output is Low | Lamp worn due to normal use | Replace lamp. |
| Mast Lights On But the Light Output is Low | Damaged or loose electrical connections | Check the mast coil cord, mast junction box and mast light connections. |
| Mast Lights On But the Light Output is Low | Generator output incorrect. | Check the incoming voltage to the ballast. Incoming voltage should be 120V +/-5V. If the voltage is incorrect, the engine speed may need to be adjusted or the generator may require service. |
| Mast Lights On But the Light Output is Low | Low transformer output | The voltage from the transformer should read approximately 400VAC as the light "strikes" (induces an arc), then drop and slowly rise back up to stabilize at 240-260VAC. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Parts
3| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 90243 | Air Filter Element | Air filter | Amazon eBay | |
| 02076 | Unit ID Tag, Vin Tag | Service part / kit | Amazon eBay | |
| 209649 | Form: SFC626B | 1 | Service part / kit | Amazon eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.