Service parts for the YD series
Grouped by system, with how many of each the parts manual calls for.
Air intake
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Standby power | 6 kW |
|---|---|
| Prime power | 6 kW |
| Oil capacity | 3.5 L |
| Alternator | YD (4-pole) |
| Voltage options | 50/60 V |
| Battery group | 74 |
| Battery voltage | 12 V |
| Max ambient | [120] °C |
Maintenance & consumables
for the Cummins/Onan J block (Series JB/JC)| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | AIR CLEANER FILTER ELEMENT | 145-289-000 | Amazon eBay | ||
| Fuel filter | fuel filter | — | 1000 hr | ||
| Oil filter | oil filter | — | 500 hr | ||
| Battery | battery charge rate adjusting resistor | — | 1200 hr | ||
| Belt | crankcase breather | — | 1000 hr | ||
| Coolant | — | 1000 hr | |||
| Oil | crankcase oil | 3.5 quarts | — | 500 hr | |
| Spark plug | ignition breaker points (Series JB) or distributor (Series JC) | — | 500 hr |
Service intervals
15| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Exhaust system | Inspect | 8 hr | Daily | |
| Generator set | Inspect | 8 hr | Daily | |
| Air cleaner | Check | 50 hr | ||
| Battery | Check | 50 hr | Check condition of the battery | |
| Crankcase oil | Change | 100 hr | First service — Change crankcase oil after the first 50 hours | |
| Fuel filter | Clean | 100 hr | Fuel filter sediment bowl | |
| Governor linkage | Clean | 100 hr | Clean and adjust (governor rod ball joints) | |
| Crankcase breather | Replace | 200 hr | Series JB | |
| Generator | Clean | 200 hr | Clean the generator | |
| Ignition breaker points | Adjust | 200 hr | Series JC; clean and adjust | |
| Spark plug | Check | 200 hr | Check the spark plug gap | |
| PCV valve | Clean | 500 hr | Series JC | |
| Starter disconnect breaker | Replace | 500 hr | Service the starter disconnect breaker | |
| Oil pan | Clean | 1000 hr | Remove and clean the oil pan | |
| Valves | Adjust | 1000 hr | Grind the valves if necessary - contact an authorized Onan dealer |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
16| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Gap | Ignition breaker point gap | 0.018-0.022 | in (0.46-0.58 mm) | |
| Gap | Ignition breaker point gap | 0.019-0.021 | in (0.48-0.53 mm) | |
| Gap | Spark plug gap | 0.025 | in (0.64 mm) | |
| Gap | Spark plug gap | 0.035 | in (0.89 mm) | |
| Gap | Starter disconnect breaker point gap | 0.020 | in (0.51 mm) | |
| Other | Distributor rotation | Clockwise | ||
| Other | Firing order | 1-2-4-3 | ||
| Other | Ignition timing (gas and combination gas/gasoline) | 35 | degrees BTC at 1800 RPM | at 1800 RPM |
| Other | Ignition timing (gasoline) | 25 | degrees BTC at 1800 RPM | at 1800 RPM |
| Speed | Dwell angle | 48-54 | degrees | |
| Torque | Cylinder head bolt torque | 28-30 | ft-lbs (38-41 N m) | |
| Torque | Generator diode stud torque | 25 | ft-lbs (33 Nm) | |
| Valve clearance | Valve clearance - exhaust (gas and combination gas/gasoline) | 0.020 | in (0.51 mm) | Cold, crank at 10-45 degrees ATC on power stroke |
| Valve clearance | Valve clearance - exhaust (gasoline) | 0.015 | in (0.38 mm) | Cold, crank at 10-45 degrees ATC on power stroke |
| Valve clearance | Valve clearance - intake (gas and combination gas/gasoline) | 0.013 | in (0.33 mm) | Cold, crank at 10-45 degrees ATC on power stroke |
| Valve clearance | Valve clearance - intake (gasoline) | 0.012 | in (0.30 mm) | Cold, crank at 10-45 degrees ATC on power stroke |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | SAE viscosity grades per ambient temperature chart (10W-30, 10W-40, 20W-40, 20W-50, 30 shown on chart) | API service classification SF or SF/CC; must have passed MS Sequence Tests (or ASTM G-IV Sequence Tests); do not use Service DS oil | 3.5 quarts | Includes 0.5 quarts (0.47 l) for the oil filter. Viscosity chart temperature range shown as -20 to 100 F. | |
| Fuel | Gasoline/propane/natural gas | High compression pistons are necessary for full rated output on natural gas. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
11Battery Charge Rate Adjustment maintenance
⚠ Batteries emit highly explosive hydrogen gas. Never smoke near a battery, and keep sparks, flames and other sources of ignition away.
- Locate the battery charge rate adjusting resistor in the outlet of the generator cooling blower.
- Shut down the set before adjusting the slide tap.
- Adjust the slide tap up to increase the charge rate if necessary to maintain a specific gravity of at least 1.260.
- Keep battery terminals clean and tight; apply a light coat of vaseline to retard corrosion.
- Fill the cells with distilled water to keep the electrolyte level up to the split rings.
Generator Rectifier Cleaning maintenance
Tools: Filtered low pressure compressed air, Torque wrench
- Remove the generator end cover for access to the rotating rectifiers.
- Use filtered, low pressure compressed air to blow away accumulated dust on the diodes.
- Torque the diode studs to 25 ft-lbs (33 Nm).
Oil Change maintenance
⚠ Hot oil can cause burns. Shut down the set before checking the oil level to prevent hot oil from blowing out on you.
- Drain the crankcase oil while the engine is still hot.
- Refill with oil of the correct API designation and SAE viscosity grade suitable for the ambient temperature.
Oil Filter Installation maintenance
- Lightly oil the gasket.
- Turn the filter on by hand until the gasket just touches the block.
- Tighten 1/2 turn more.
Out-of-Service Protection maintenance
- Perform all scheduled maintenance.
- Change the oil and attach a tag indicating the viscosity grade.
- Pour one ounce of rust inhibiting oil (or SAE Grade 10) into each cylinder, crank the engine several times and replace the spark plugs.
- Plug the exhaust outlet to prevent the entrance of insects, dust and moisture.
- Lightly wipe with grease or oil metal parts that would otherwise rust.
- Disconnect the battery (negative [-] cable first) and store it following standard procedures.
- Cover the set to protect it from dust and moisture.
Returning an Out-of-Service Set to Service maintenance
- Unplug the exhaust and remove the protective cover.
- Change the oil if the viscosity grade recorded on the tag is not suitable for the current ambient temperature.
- Service the battery and connect it (negative [-] cable last).
- See Operation for starting and operating the set.
Break-in Procedure operation
⚠ Running the set continuously with less than 1/2 full rated load during the first hundred hours can result in poor seating of the piston rings and consequent problems with ring blowby and high oil consumption.
- Connect 1/2 of the full rated load for the first half hour of operation.
- Connect 3/4 of the full rated load for the next half hour of operation.
- Operate with the full rated load connected any time thereafter.
- Drain and replace the engine oil after the first 50 hours of operation.
Combination Gas/Gasoline Sets operation
- Select the fuel to be used and close the supply valve for the other fuel.
- Engage the choke lock wire to keep the choke open when using gas fuel and release it when using gasoline.
Connecting the Load operation
⚠ Overloading can cause the generator to overheat and fail. The load may exceed the nameplate rating only momentarily, such as during the starting of a large motor.
- When possible, allow the set to warm up before connecting the full load.
- When possible, connect the load in steps.
- Occasionally connect the full rated load to burn off carbon deposits formed in the exhaust system during light-load operation.
Starting operation
⚠ Pressure cooled engines can quickly overheat and be damaged if run without the front air shroud/access cover in place.
- Check the fuel and oil levels.
- Make sure all the air shrouds and service access covers are in place.
- Press the START/STOP switch to START until the engine starts; the starter is disengaged automatically by the start disconnect switch.
- Do not crank for more than 30 seconds at a time; allow 60 seconds between cranks.
- A new set may not start right away if spark plug electrodes are coated by rust inhibiting oil; remove spark plugs and clean the oil off.
- The oil pressure gauge should indicate at least 20 psi.
- Connect the load and follow the break-in procedure for initial start-up.
Stopping operation
- Disconnect the load and let the generator set run for 10 minutes to cool off.
- Press the START/STOP switch to STOP until the engine stops.
- If a safety circuit stops the engine (high engine temperature or low oil pressure), determine the cause and service or repair before returning the set to service.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Voltage reconnection
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 110/190 | 3 | V1 | 50 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 110/220 | 1 | V1 | 50 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 115/230 | 1 | V2 | 50 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 118/200 | 3 | V4 | 50 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 120/208 | 3 | V1 | 60 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 120/240 | 1 | V1 | 60 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 120/240 | 1 | V3 | 50 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 127/220 | 3 | V4 | 50 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 139/240 | 3 | V4 | 60 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 230/400 | 3 | V2 | 50 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 240/416 | 3 | V3 | 50 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 254/440 | 3 | V2 | 60 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 254/440 | 3 | V4 | 50 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 277/480 | 3 | V3 | 60 Hz; decoded from Figure 3-4 (OCR degraded) | |
| 347/600 | 3 | V4 | 60 Hz; decoded from Figure 3-4 (OCR degraded) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What size generator is the Cummins/Onan YD series?
The Cummins/Onan YD series is rated 6 kW standby.
What engine is in the Cummins/Onan YD series?
The Cummins/Onan YD series is powered by the Cummins/Onan J block (Series JB/JC) engine.
What is the oil capacity of the Cummins/Onan YD series?
The Cummins/Onan YD series has an engine oil capacity of 3.5 liters (3.7 US quarts), per the manufacturer specification sheet.
What voltage does the Cummins/Onan YD series produce?
The Cummins/Onan YD series is offered in 50/60 V.
Which alternator is fitted to the Cummins/Onan YD series?
The Cummins/Onan YD series uses a YD alternator. It has 4 poles.
What air filter does the Cummins/Onan YD series use?
The Cummins/Onan YD series uses air filter part number 145-289-000.
Repair guides
5- Battery Charge Rate Adjustment
- Generator Rectifier Cleaning
- Oil Filter Installation
- Returning an Out-of-Service Set to Service
- Starting
Step-by-step procedures compiled from the Cummins/Onan service manual for this model.
Parts
4| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 145-289-000 | AIR CLEANER FILTER ELEMENT | 1 | Air filter | Amazon eBay |
| 145-367-000 | BATTERY CHARGE RATE ADJUSTING RESISTOR | 1 | Service part / kit | Amazon eBay |
| 42-1817 | FLEXIBLE CONDUIT | 1 | Service part / kit | Amazon eBay |
| 967-0120 | Safety Precautions Manual | Service part / kit | Amazon eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| 100% | 4.7 | 1.24 |