Home›Repair guides›Cummins/Onan›Returning an Out-of-Service Set to Service

Cummins/Onan — Returning an Out-of-Service Set to Service

Maintenance · Generator set

From a Cummins/Onan owner's manual — check it applies to your exact model before use.

Applies to: Cummins/Onan YD series, Cummins/Onan J block (Series JB/JC) engine

Procedure

  1. Unplug the exhaust and remove the protective cover.
  2. Change the oil if the viscosity grade recorded on the tag is not suitable for the current ambient temperature.
  3. Service the battery and connect it (negative [-] cable last).
  4. See Operation for starting and operating the set.

Full service-parts list: Cummins/Onan YD series →

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.