Home›Repair guides›Cummins/Onan›Generator Rectifier Cleaning

Cummins/Onan — Generator Rectifier Cleaning

Maintenance · Generator rotating rectifiers

From a Cummins/Onan owner's manual — check it applies to your exact model before use.

Applies to: Cummins/Onan YD series, Cummins/Onan J block (Series JB/JC) engine

Procedure

  1. Remove the generator end cover for access to the rotating rectifiers.
  2. Use filtered, low pressure compressed air to blow away accumulated dust on the diodes.
  3. Torque the diode studs to 25 ft-lbs (33 Nm).

Tools required

  • Filtered low pressure compressed air Amazon
  • Torque wrench Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Diode stud torque 25 ft-lbs (33 Nm)

Full service-parts list: Cummins/Onan YD series →

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.