Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 10 kW |
| Standby kVA | 14 |
| Prime power | 10 kW |
| Controller | PowerCommand 1.1, PowerStart 0600 |
| Alternator | Cummins/Onan DS338-CPGK, DS340-CPGK, DS342-CPGK, DS339-CPGK, DS341-CPGK, DS343-CPGK (Class H insulation) |
| Voltage options | 230 V, 240 V, 220/380 V, 230/400 V, 240/416 V |
| Phase | 3 |
| Power factor | 1.0 |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 1667×930×1282 mm |
| Dry weight | 601 kg |
| Sound level | 77.0 dBA @ 1 m |
| Fuel tank | 1000.0 L |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Dry replaceable element | — | find | ||
| Fuel filter | Spin on fuel filters with water separator | — | find | ||
| Oil filter | Spin on full flow filter, filtration efficiency 25 micron 99% (min) | — | find | ||
| Belt | N/A | — | find | ||
| Coolant | Antifreeze 50/50 (Ethylene glycol) | — | |||
| Oil | Cummins heavy-duty engine oil | — |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Common questions
What is the power rating of the Cummins/Onan C12 D6?
The Cummins/Onan C12 D6 is rated 10 kW standby (14.0 kVA).
What engine does the Cummins/Onan C12 D6 use?
The Cummins/Onan C12 D6 is powered by the Cummins/Onan C12D6T engine.
What fuel does the Cummins/Onan C12 D6 use?
The Cummins/Onan C12 D6 runs on Diesel.
What alternator does the Cummins/Onan C12 D6 use?
The Cummins/Onan C12 D6 uses a Cummins/Onan DS338-CPGK, DS340-CPGK, DS342-CPGK, DS339-CPGK, DS341-CPGK, DS343-CPGK alternator. Insulation class H.
Troubleshooting
17Fault codes
| Code | Meaning |
|---|---|
| 59 | High AC voltage shutdown |
| 27 | Low AC voltage shutdown |
| 81 u | Under frequency shutdown |
| 81 o | Over frequency shutdown/warning |
| 51 | High Current warning/shutdown |
Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| Battery voltage warning | Status of battery charging system (failure) | |
| Emergency stop signal is received | The generator set immediately shuts down and cannot run or crank with the E-stop switch engaged. | |
| Time delay of 0-600 seconds prior to shutdown after signal to stop in normal operation modes | Default for both time delay periods is 0 seconds. | |
| Undervoltage sensor pickup and dropout adjustable from 85-100% and 75-98% | Dropout adjustable delay from 0.1-30 sec. | |
| Overvoltage sensor dropout adjustable from 105-135% of nominal | Dropout adjustable delay from 0.5-120 sec. | |
| Over/under frequency sensor underfrequency sensing pickup and dropout adjustable from 85-100% and 70-85% | Dropout adjustable delay from 0.1-15 sec. | |
| Over/under frequency sensor overfrequency sensing dropout adjustable from 105-115% of nominal | Dropout adjustable delay from 0.1-15 sec. | |
| Time delay start and stop (cooldown) configurable for time delay of 0-300 seconds prior to starting after receiving a remote start signal | Control provides retransfer time delays including time delay emergency to normal (0-1800 sec), programmed transition delay (0-600 sec), and time delay engine cooldown (0-3600 sec). | |
| Low lube oil pressure warning/shutdown | Level is pre-set to match the capabilities of the engine used. Control includes time delays to prevent nuisance shutdown signals. | |
| High coolant temperature warning/shutdown | Level is pre-set to match the capabilities of the engine used. Control includes time delays to prevent nuisance shutdown signals. | |
| Low coolant temperature warning | Indicates that engine temperature may not be high enough for 1 min. and start or proper load acceptance. | |
| Sensor failure indication | Logic is provided on the base control to detect analog sensor or interconnecting wiring failures. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | |||
| Standby |