Home›Caterpillar›Caterpillar C1.7

Caterpillar C1.7 Generator Set

Caterpillar C1.7 generator set: . Specifications, engine details, filters, oil capacity and 3 document types.

3
Document types

How to read your Caterpillar serial & model number →

Specifications

Ratings spec sheet not in our library yet — see the documents below.

Filters & service parts

model family
ItemSpecCapacityPart #Interval
Air filter—500 hr
Fuel filter—1000 hr
Oil filter—250 hr
Battery—18000 hr
Belt—
Coolant—2000 hr
Oil—250 hr
Spark plug—500 hr

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.

Service intervals

27
ItemActionHoursMonthsNotes
Fuel Tank Water and SedimentDrain50 hrEvery 50 Service Hours or Weekly
Cooling System Coolant Sample (Level 1)Test250 hrEvery 250 Service Hours - Obtain
Engine Oil SampleTest250 hrEvery 250 Service Hours - Obtain
Battery Electrolyte LevelCheck500 hr12 moEvery 500 Service Hours or 1 Year
BeltsInspect500 hrEvery 500 Service Hours - Inspect/Adjust
Engine Air Cleaner ElementReplace500 hrEvery 500 Service Hours
Engine Oil and FilterChange500 hr12 moEvery 500 Service Hours or 1 Year
Fuel System Primary Filter (Water Separator) ElementReplace500 hr12 moEvery 500 Service Hours or 1 Year
Fuel System Secondary FilterReplace500 hr12 moEvery 500 Service Hours or 1 Year - replace primary and secondary at the same time
Hoses and ClampsInspect500 hr12 moEvery 500 Service Hours or 1 Year - Inspect/Replace
RadiatorClean500 hr12 moEvery 500 Service Hours or 1 Year
engineOther500 hrCat compact diesel lineup offers 500-hour maintenance intervals and single-side service access
Alternator and Fan BeltsReplace1000 hrEvery 1000 Service Hours
Engine Valve LashCheck1000 hrEvery 1000 Service Hours
TurbochargerInspect1000 hrEvery 1000 Service Hours
Engine Crankcase Breather ElementReplace1500 hrEvery 1500 Service Hours
AlternatorInspect2000 hrEvery 2000 Service Hours
Engine MountsInspect2000 hrEvery 2000 Service Hours
Starting MotorInspect2000 hrEvery 2000 Service Hours
Cooling System Coolant (DEAC)Change3000 hr24 moEvery 3000 Service Hours or 2 Years
Cooling System Water Temperature RegulatorReplace3000 hrEvery 3000 Service Hours
Exhaust Gas Recirculation ValveClean3000 hrEvery 3000 Service Hours - also clean connecting pipe and exhaust cooler; reset EGR maintenance timer; 100 hours allowed to complete
Water PumpInspect3000 hrEvery 3000 Service Hours
Aftercooler CoreInspect4000 hrEvery 4000 Service Hours
Cooling System Coolant Extender (ELC)Other6000 hr36 moEvery 6000 Service Hours or 3 Years - Add
Cooling System Coolant (ELC)Change12000 hr72 moEvery 12 000 Service Hours or 6 Years
Cooling System Coolant Sample (Level 2)Test12 moEvery Year - Obtain

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

25
TypeItemValueUnitCondition
ClearanceFan clearance (A) between cover edge and fan blade tip10mmfour cylinder turbocharged engine
ClearanceFan clearance (A) between cover edge and fan blade tip5mmthree cylinder engine
ClearanceFan clearance (A) between cover edge and fan blade tip8mmfour cylinder turbocharged aftercooled engine
OtherEngine rotation (flywheel end)Counterclockwise
OtherNew belt tension400 to 489Nnew belt
OtherUsed belt tension267 to 356Nused belt in operation 30 minutes or more at rated speed
PressureCooling system filler cap pressure110kPafour cylinder engine
PressureCooling system filler cap pressure95kPathree cylinder engine
PressureEngine oil pressure with SAE10W30207 to 413kPaat rated rpm
PressureMaximum air pressure for cleaning purposes205kPa
PressureMaximum water pressure for cleaning purposes275kPa
SpeedOverspeed limit (700 RPM above the given speed)2800RPMC1.7 turbocharged; C2.2 turbocharged; C2.2 turbocharged with charge cooler
TemperatureJacket water coolant temperature typical range82 to 96°C
TemperatureMaximum allowable coolant temperature with pressurized cooling system at 90 kPa112°C
TorqueAir cleaner service indicator2N·m
TorqueAlternator belt adjuster bolt (1) and bolt (2)25N·m
TorqueAlternator belt nut (4) and bolt (5)25N·m
TorqueBelts adjust bolt (1), bolt (3), nut and bolt (4)22N·m
TorqueCrankcase breather cap assembly10N·m
TorqueFuel filter bowl10N·m
TorqueRadiator drain plug (2) three cylinder and (3) four cylinder turbocharged4N·m
TorqueRadiator drain plug (4) four cylinder turbocharged aftercooled6N·m
TorqueSecondary fuel filter vent screw24N·m
Valve clearanceExhaust valve lash0.20mmcold
Valve clearanceInlet valve lash0.20mmcold

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantCaterpillar EC-1 (Cat ELC) - Preferred1:1 mixture of water and glycol; Cat ELC service life 12000 hours or six years
Engine oilCat DEO-ULS8.9 LC2.2 Turbocharged and Turbocharged Aftercooled crankcase oil sump refill capacity
Engine oilCat DEO-ULS SAE 10W-30EMA; API; SAE4.5 LC1.7 crankcase oil sump refill capacity
Engine oilCat DEO-ULS SAE 15W-40EMA; API; SAEPasses proprietary tests (piston ring sticking, oil control, wear, soot)
Engine oillow sulfated ash oilRequired for U.S. EPA Tier 4 Final, EU Stage IV engines.
FuelUltra Low Sulfur Diesel (ULSD)Contains less than or equal to 15 parts per million sulfur (mg/kg); required for U.S. EPA Tier 4 Final, EU Stage IV engines. B20 biodiesel capability available.
FuelUltra low sulfur diesel (ULSD)EPA prescribed fuelRefer to SEBU6251 for distillate fuel specification
GreaseCaterpillar greases (moderate to high performance)Purge joint when switching grease or supplier

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

2
CodeNameMeaningSeverityAction
5838-14EGR Valve Malfunction : Special InstructionActive at 3100 hours if cleaning and reset not performed; amber warning lamp flashes and the engine is deratedWarningPerform the EGR valve cleaning and reset the EGR maintenance timer.
5838-31EGR Valve MalfunctionActive at 3000 hours; amber warning lamp becomes solid; informs operator that cleaning and reset are requiredWarningClean the EGR valve, connecting pipe and exhaust cooler and reset the EGR maintenance timer within 100 hours.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

10
Engine Valve Lash - Check adjustment

⚠ Ensure the engine cannot be started while this maintenance is performed.

⚠ Hot engine components can cause burns.

  1. Ensure the engine cannot be started and is stopped.
  2. Measure the inlet valve lash; specification 0.20 mm.
  3. Measure the exhaust valve lash; specification 0.20 mm.
  4. Adjust valves per Systems Operation, Testing and Adjusting sequence.
Alternator and Fan Belts - Replace (Single-V Belt) maintenance
  1. If the engine is equipped with fan guards, remove the fan guards.
  2. Loosen bolt (1) and bolt (2) on the adjuster link.
  3. Loosen nut (4) and bolt (5).
  4. Push the alternator toward the engine and remove the belt.
  5. Position the new belt onto the alternator, water pump and crankshaft pulleys.
  6. Slide the alternator away from the engine to tighten the belt.
  7. Tighten bolt (1) and bolt (2) to a torque of 25 N·m.
  8. Tighten nut (4) and bolt (5) to a torque of 25 N·m.
  9. Install the fan guards.
  10. Check the belt tension again after 20 hours of engine operation.
Battery - Replace maintenance

⚠ Batteries give off combustible gases which can explode.

  1. Switch the engine to the OFF position and remove all electrical loads.
  2. Turn off and disconnect any battery chargers.
  3. Disconnect the NEGATIVE '-' cable from the battery terminal.
  4. Disconnect the POSITIVE '+' cable from the battery terminal.
  5. Remove the used battery and recycle it.
  6. Install the new battery.
  7. Connect the cable from the starting motor to the POSITIVE '+' terminal.
  8. Connect the NEGATIVE '-' cable to the NEGATIVE '-' terminal.
Cooling System Coolant (ELC) - Change maintenance

⚠ Pressurized System: Hot coolant can cause serious burns.

  1. Stop the engine and allow it to cool; loosen the filler cap slowly to relieve pressure.
  2. Remove the engine drain plug and the radiator drain plug; drain the coolant.
  3. Flush the cooling system with clean water to remove debris.
  4. Close the drain valve and install the drain plugs.
  5. Fill the cooling system with clean water and install the filler cap.
  6. Run the engine at low idle until temperature reaches 49 °C to 66 °C.
  7. Stop the engine and allow it to cool; drain and flush with clean water.
  8. Fill the cooling system with Extended Life Coolant (ELC).
  9. Run the engine at high idle for 1 minute to purge air; stop the engine.
  10. Maintain coolant at the maximum mark and install the filler cap.
Engine Crankcase Breather Element - Replace maintenance

⚠ Hot oil and hot components can cause personal injury.

  1. Ensure dirt cannot enter the breather assembly and place a container under it.
  2. Remove clip (3) and hose (4) from cap (2); remove cap (2) from body (1).
  3. Remove filter element (5) and O ring seal (6); discard.
  4. Install a new O ring seal (6) and a new filter element (5) into cap (2).
  5. Install the cap assembly into the main body and tighten to 10 N·m.
  6. Install hose (4) and clip (3); clean away any split fluid.
Engine Oil and Filter - Change maintenance

⚠ Hot oil and hot components can cause personal injury.

⚠ Do not fill the oil filters with oil before installing them.

Tools: 1U-8760 Chain Wrench, 175-7546 Oil Filter Cutter Gp

  1. Drain the crankcase with the engine stopped and the oil warm.
  2. Remove the oil filter with a 1U-8760 Chain Wrench.
  3. Cut the oil filter open with a 175-7546 Oil Filter Cutter Gp to inspect debris.
  4. Clean the sealing surface of the cylinder block.
  5. Apply clean engine oil to the new oil filter seal.
  6. Install the oil filter and tighten by hand per the filter instructions.
  7. Fill the crankcase with the correct amount of oil.
  8. Crank the engine with the fuel OFF to fill the oil filters.
  9. Start the engine and run at LOW IDLE for 2 minutes.
  10. Stop the engine and allow oil to drain back for a minimum of 10 minutes.
  11. Check the oil level between the ADD and FULL marks.
Fuel System - Prime maintenance

⚠ Do not loosen the high-pressure fuel lines to purge air.

  1. Ensure the fuel tank is full and any fuel valve is in the ON position.
  2. For gravity feed systems, loosen the vent screw and allow fuel to flow.
  3. When air-free fuel comes from the vent screw, tighten it by hand.
  4. Loosen the vent screw on the secondary fuel filter.
  5. Turn the keyswitch to RUN to operate the electric priming pump.
  6. When air-free fuel comes from the vent screw, tighten it to 24 N·m.
  7. Operate the electric priming pump for 2 minutes.
  8. Turn the keyswitch to the OFF position.
  9. Crank the engine and run at low idle for a minimum of 5 minutes.
  10. Ensure the fuel system is free from leaks.
Starting the Engine operation

⚠ Do not use aerosol types of starting aids such as ether.

⚠ Do not start the engine under load.

  1. Disengage any equipment that is driven by the engine.
  2. Turn the keyswitch to RUN and wait until the glow plug lamp extinguishes.
  3. Turn the keyswitch to START; the starter motor cranks the engine.
  4. If the engine fails to start within 30 seconds, wait two minutes before retrying.
  5. Allow the keyswitch to return to RUN after the engine starts.
  6. Allow constant speed engines to reach operating speed with no load; run 2 minutes before load.
Stopping the Engine operation

⚠ Stopping the engine immediately after it has been working under load can result in overheating and accelerated wear.

  1. Remove the load from the engine and reduce the engine speed to low idle.
  2. Allow the engine to idle for 5 minutes to cool the engine.
  3. Turn the ignition keyswitch to the OFF position.
Welding on Engines with Electronic Controls repair

⚠ Do not use ECM or ECM sensors or their grounding points for grounding the welder.

  1. Stop the engine and remove the electrical power from the ECM.
  2. Ensure that the fuel supply to the engine is turned off.
  3. Disconnect the negative battery cable; open the battery disconnect switch if installed.
  4. Disconnect all electronic components from the wiring harnesses.
  5. Connect the welder ground clamp directly to the component being welded, close to the weld.
  6. Protect the wiring harnesses from welding debris and spatter.
  7. Use standard welding procedures to weld the materials together.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts

1model family
Part #DescriptionQtySystem
M0064264-06Fuel Injection Lines - Install1Service part / kit Amazon eBay

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Available documents

Engine spec — LECH3874-07 (Caterpillar)Engine spec — LEGH0001-02 (Caterpillar)Engine spec — LEGH0001-03 (Caterpillar)Engine spec — LEHH6412 (Caterpillar)Engine spec — LFDH5502-01 HR (Caterpillar)Reference — Industrial rating guide (Caterpillar)Reference — LEDH7559 (Caterpillar)Reference — LEGH0002 (Caterpillar)Owner's manual — C1.7-2.2-Engine-Manual-M0064264EN-US (Caterpillar)

This page was generated from the 9 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.