The Northern Lights M944W is a 12.5 L 6-cylinder turbocharged engine rated at 1500 rpm, producing up to 200 kW. It powers generator sets from Northern Lights, including the M944. It holds 10 L (2.6 gal) of oil and 10 L (2.6 gal) of coolant.
Maintenance schedule
| Item | Spec | Capacity | Part # | Interval | |
|---|
| Air filter | Air cleaner | | 24-01201 | 250 hr | Amazon $50.34 eBay $44.99 |
| Fuel filter | 50/50 ethylene-glycol heavy-duty diesel engine coolant | | 24-51201 | 2000 hr | Amazon eBay $33.57 |
| Oil filter | Secondary fuel filter | | 24-51201 | 250 hr | Amazon eBay $33.57 |
| Battery | sealed batteries | | — | 500 hr | |
| Belt | alternator drive belt | | — | 500 hr | |
| Coolant | 50/50 ethylene-glycol heavy-duty diesel engine coolant | 3.0 gal. | — | 2000 hr | |
| Oil | 50/50 ethylene-glycol heavy-duty diesel engine coolant | 3.0 gal. | — | 2000 hr | |
| Spark plug | spark plugs | | — | 500 hr | |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
Common questions
What is the oil capacity of the Northern Lights M944W?
The Northern Lights M944W engine has an oil capacity of 10.0 liters.
What is the displacement of the Northern Lights M944W?
The Northern Lights M944W has a displacement of 12.5 liters with 6 cylinders.
Which generators use the Northern Lights M944W engine?
The Northern Lights M944W powers 1 generator set(s), including Northern Lights M944.
How often should you change the oil in the Northern Lights M944W?
The Northern Lights M944W oil change interval is every 2000 hours.
What is a common problem with the Northern Lights M944W engine?
A commonly reported issue on generators using the Northern Lights M944W is: Temperature gauge above 205° F (96° C). Fix: Shut off the engine immediately. Use the Trouble Shooting Guide on page 25 to isolate the cause of the overheat. Allow the engine to cool and then remove the cap slowly using protective clothing. Make repairs and restart after the temperature gauge registers below 200° F (94° C). Watch the temperature gauge regularly and turn off the unit if the temperature rises above 205° F (96° C). Repeat troubleshooting..