Home›Engines›John Deere RG6090HF485

John Deere RG6090HF485 Engine

The John Deere RG6090HF485 is a 9 L 6-cylinder turbocharged engine rated at 1800 rpm, producing up to 384 kW. It powers generator sets from Generac and Magnum, including the MMG320, MMG320 and MMG320 Super Start. It holds 70.9 L (18.7 gal) of coolant.

Also known as: John Deere RG6090HF485

Part of the John Deere 6090 engine family — 43 variants share parts & fitment.

9.0 L
Displacement
6
Cylinders
1800 rpm
Rated speed
384 kW
Gross power

Engine specifications

Coolant capacity70.9 L
Displacement9.0 L
Cylinders6
AspirationTurbocharged
Rated speed1800 rpm
Gross power384 kW

Generator sets powered by this engine

3

Shared across brands: Generac, Magnum

How to read your John Deere engine serial & model number →

Common problems

15
  • WrnMaintenance — The period for servicing is set by the WrnMaintenance setpoint. The protection comes active if the running hours of the engine reach this value. 31
  • Wrn RA15 fail — Warning alarm in case of lost connection to IGL=RA15 module. 30
  • Wrn ECU Alarm — ECU alarm list is not empty. 29
  • Vgen<, > — The generator voltage is out of limits given by Gen <V and Gen <V setpoints. 27
  • Vgen unbal — The generator voltage is unbalanced more than the value of Volt unbal setpoint. 28
  • Underspeed — During starting of the engine, when the RPM reaches the value of Starting RPM setpoint, the starter is switched off and the speed of the engine can drop under Start RPM again. Then the underspeed protection becomes active. Protection evaluation starts 5 seconds after start up. 26
  • TimingSensor SPN:637
  • PositionSensor SPN:636
  • Overspeed or underspeed shut down
    Cause: Engine speed out of adjustment (frequency above or below 60.0 Hz)
    Fix: Disconnect all loads and restart the generator, read the frequency (Hz) on the LCD display (with no loads the frequency should read 60.0 Hz); If the frequency is above or below 60.0 Hz, adjust the engine speed — see the engine manual for throttle adjustments on mechanical governed units and see the electronic governor manual for electronically controlled units
  • Overcrank shut down
    Cause: Fuel level low; Fuel pump not operating properly; Air filter blocked; Engine will not start
    Fix: Check the fuel level in the tank; Check for proper operation of the fuel pump; Check air filter for blockage; Consult the engine operation and maintenance manual for additional information on troubleshooting starting problems
  • Low oil pressure shut down
    Cause: Engine oil level low; Oil leaks; Oil pressure sender faulty
    Fix: Check the level of the engine oil with the dipstick and add oil if required; Visually inspect the engine for oil leaks; Restart the unit and verify the loss of oil pressure, shutting the engine down immediately if the oil pressure value does not read 5 psi (34 kPa) within five seconds; Check the oil pressure sender and refer to the troubleshooting section of the engine operation and maintenance manual
  • Low fuel level shut down
    Cause: Fuel level low; Leaks in the fuel tank; Fuel level sender and connecting wiring damaged
    Fix: Check the fuel level on the LCD window and confirm the generator is sitting level to ensure an accurate reading; Check for leaks in the fuel tank; Check the fuel level sender and the connecting wiring for damage and check for continuity between the sender and the engine controller
  • Low coolant level shut down
    Cause: Coolant level low; Leaks in coolant hoses, engine block or water pump; Coolant mixed with engine oil
    Fix: Allow the engine to cool; Check the coolant level in the radiator, add coolant until it is 3/4" below the filler neck and secure the radiator cap; Inspect coolant hoses, engine block and water pump for visible leaks; Check the engine oil to verify no coolant has mixed with it and consult the engine operation and maintenance manual
  • Intake Temp SPN:105
  • InjectorCyl#6 SPN:656

Compiled from service & troubleshooting documentation across every generator set that uses the John Deere RG6090HF485.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterpaper element—
Battery1000 CCA—
CoolantConsult the engine operation and maintenance manual for coolant recommendations and proper mixture—
OilJohn Deere PLUS-50 or equivalent—

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service intervals

21
ItemActionHoursMonthsNotes
Engine oil and oil filterChange250 hrFirst service — Change after first 100 hours, then every 250 hours. If John Deere PLUS-50 or equivalent is used, every 500 hours.
Oil vapor recirculation system/non-return valveCheck250 hr
Air intake hoses, connections, and systemCheck500 hr12 mo
BatteryInspect500 hr12 moService battery
Belt tensioner and belt wearCheck500 hr12 moAt 500 hour/12 month interval, remove belt and check for wear; inspect pulleys and bearings
Coolant pump weep hole foam filterCheck500 hr12 mo
Cooling systemCheck500 hr12 mo
Engine ground connectionCheck500 hr12 mo
Engine mountsCheck500 hr12 mo
Fuel filters/water separatorReplace500 hr12 moReplace fuel filters/clean water separator
Generator drive plate torqueCheck500 hr12 moSee page 45
Leveling jack(s)Lubricate500 hr12 mo
Oil vapor recirculation filterReplace500 hr12 mo
ThermostatsTest500 hr12 mo
Air cleaner elementsReplace2000 hr24 mo
Alternator and fan beltsReplace2000 hr24 mo
CoolantCheck2000 hr24 moAdd coolant
Electrical wiring and connectionsCheck2000 hr24 mo
Fuel systemDrain2000 hr24 moBleed fuel system
FusesCheck2000 hr24 mo
Engine oil filterChange8803 hrLast changed 10/25/2024, 8803HRS

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

27
TypeItemValueUnitCondition
OtherEngine hours at test steps8801.8 / 8801.9 / 8802.1 / 8802.4 / 8802.6 / 8802.9 / 8803hourswarm up through cool down
OtherFine voltage adjustment window (V Detect)45seconds
OtherFuel level low fuel shutdown setpoint5%
OtherFuel level low fuel warning setpoint15%
OtherLoad bank output (start / 15min / 30min / 45min / 1hr)270kWat ~324-327 A per phase, 482-484 V, 60 Hz, power factor 1
PressureAir filter restriction indicator - replace element20in. H2O
PressureAir filter restriction indicator - replace primary air cleaner25in. H2O
PressureEngine oil pressure, low oil pressure shut downless than 20psi (138 kPa)
PressureEngine oil pressure, normal operating35-80psi (241-552 kPa)engine running
PressureEngine oil pressure, verify within 5 seconds of start5psi (34 kPa)within 5 seconds of start
PressureOil pressure (warm up / start / 15min / 30min / 45min / 1hr / cool down)44 / 36 / 35 / 34 / 32 / 32 / 36not statedload bank test 10/25/2024
SpeedGenerator frequency, no load60.0Hzno load
SpeedOperating speed1800rpm
TemperatureAmbient temperature (warm up / start / 15min / 30min / 45min / 1hr / cool down)49 / 49°F / 49°F / 50°F / 50°F / 50°F / 50°F°Fload bank test 10/25/2024
TemperatureCoolant temperature (warm up / start / 15min / 30min / 45min / 1hr / cool down)104 / 185°F / 186°F / 186°F / 186°F / 188°F / 165°F°Fload bank test 10/25/2024
TemperatureCoolant temperature minimum display100°F (38°C)
TemperatureMaximum water/coolant temperature shut down230°F (110°C)
TemperatureViscous fan clutch temperature range170-200°F (77-93°C)
TorqueGenerator drive plate bolts33ft-lb (45 Nm)
TorqueShorting (link) board hardware25ft-lbs
TorqueTrailer wheel lug nuts, first pass20-25ft-lbs (27-33 Nm)
TorqueTrailer wheel lug nuts, second pass50-60ft-lbs (67-81 Nm)
TorqueTrailer wheel lug nuts, third pass90-120ft-lbs (122-162 Nm)
VoltageBattery voltage, normal reading on 12 volt systems13-14Vengine running
VoltageBattery voltage, normal reading on 24 volt systems24-26Vengine running
VoltageDC voltage (all steps)13.7Vload bank test 10/25/2024
VoltageVoltage regulation+/- 1%

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant60/40Cold weather applications
Engine oilJohn Deere PLUS-50 or equivalentConsult the engine operation and maintenance manual for the proper grade of oil, including special operating conditions. If John Deere PLUS-50 or equivalent is used, oil can be changed every 500 hours.
Fueldiesel459.0 galSteel, single wall fuel tank; 24 hr. run time – full load
GreaseHigh quality grease made specifically for lubrication of wheel bearingsTrailer wheel bearings; minimum lubrication every 12 months or 12,000 miles (19,312 km)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

31
CodeNameMeaningSeverityAction
AnInIOM SdAnInIOM SdShutdown alarm configurable on the input of IG-IOM/IGS-PTM.Shutdown
AnInIOM WrnAnInIOM WrnWarning alarm configurable on the input of IG-IOM/IGS-PTM.Warning
Battery FlatBattery Flat (low battery)If the controller switches off during starting sequence due to bad battery condition, it doesn't try to start again and activates this protection.Shutdown
Binary InputBinary InputConfigurable warning/shutdown alarms on the inputs of IL-NT.
ChrgAlternFailChrgAlternFailFailure of the alternator to charge the battery.Warning
EmergencyStopEmergencyStopIf the input Emergency Stop is opened or the red E-Stop button is pushed, shutdown is immediately activated.Shutdown
Engine Temp SdEngine Temp SdWater temperature is greater than Sd Water Temp setpoint.Shutdown
Engine Temp WrnEngine Temp WrnWater temperature is greater than Wrn Water Temp setpoint.Warning
Fgen<, >Fgen<, >The generator frequency is out of limits given by Gen >f and Gen <f setpoints.Shutdown
Fuel Level SdFuel Level SdFuel level is smaller than Sd Fuel Level setpoint (5%).Shutdown
Fuel Level WrnFuel Level WrnFuel level is smaller than Wrn Fuel Level setpoint (15%).Warning
GCB failGCB failFailure of the generator circuit breaker.Shutdown
Igen unblIgen unblThe generator current is unbalanced.Shutdown
Low BackupBattLow BackupBattRTC backup battery is flat (low).Warning
Oil Press SdOil Press SdOil pressure is smaller than Oil Press Sd setpoint.Shutdown
Oil Press WrnOil Press WrnOil pressure is smaller than Oil Press Wrn setpoint.Warning
OverloadOverloadThe load is greater than the value given by Overload setpoint.Shutdown
OverspeedOverspeedThe protection comes active if the speed is greater than Overspeed setpoint.Shutdown
ParamFailParamFailWrong checksum of parameters. Happens typically after downloading new firmware or changing of the parameter. The controller stays in INIT mode.Check all parameters, write at least one new parameter.
PickupFaultPickupFaultFailure of the magnetic pick-up sensor for speed measurement.Shutdown
Sd IOM failSd IOM failIOM/IGS-PTM module.Shutdown
SprinkIActiveSprinkIActiveThe protection is active if the output Sprinkler is closed.Warning
Start failedStart failedUnit did not start.Shutdown
Stop failStop failUnit did not stop.Shutdown
UbatUbatBattery voltage is out of limits given by Batt Undervolt setpoints.Warning
UnderspeedUnderspeedDuring starting, when the RPM reaches Starting RPM setpoint the starter switches off and speed can drop under Start RPM again; underspeed protection becomes active. Evaluation starts 5 seconds after start up.Shutdown
Vgen unbalVgen unbalThe generator voltage is unbalanced more than the value of Volt unbal setpoint.Shutdown
Vgen<, >Vgen<, >The generator voltage is out of limits given by Gen <V and Gen >V setpoints.Shutdown
Wrn ECU AlarmWrn ECU AlarmECU alarm list is not empty.Warning
Wrn RA15 failWrn RA15 failWarning alarm in case of lost connection to IGL=RA15 module.Warning
WrnMaintenanceWrnMaintenanceThe period for servicing is set by the WrnMaintenance setpoint. The protection comes active if the running hours of the engine reach this value (250 hours).Warning

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Adjusting the Display Back Lighting adjustment
  1. Press and hold Enter.
  2. Press the up or down buttons on the Diagnostics keypad to increase or decrease brightness.
  3. Release the Enter button when the desired brightness is attained.
Changing Output Voltage adjustment

⚠ NEVER ATTEMPT TO CHANGE THE VOLTAGE WHILE THE ENGINE IS RUNNING. LETHAL VOLTAGE MAY BE PRESENT AT THE CONNECTION LUGS ON THE SHORTING (LINK) BOARD.

Tools: Wrench, Torque wrench

  1. Shut the generator down and set main circuit breaker and control power switch to OFF.
  2. Remove all 1/2 in. nuts holding the shorting (link) board.
  3. Move the board to the lower position for 480/277V 3Ø or the upper position for 208/120V 3Ø.
  4. Replace all hardware and tighten to 25 ft-lbs of torque.
  5. Reinstall the reconnect box door and start the generator per the Pre-Start Check List.
Resetting of the Time to Service Reminder adjustment
  1. With the unit shut down, power up the controller with the Control On/Off toggle switch.
  2. Press Page Select, move the cursor down to Engine Protect and press Enter.
  3. Press Enter; the current run time in hours appears under WrnMaintenance.
  4. Press the up arrow and reset the current run time hour setting to 250.
  5. Press Enter to save the current run time hour setting.
  6. Move the CONTROL ON/I toggle switch to the CONTROL OFF/O position.
Checking Generator Drive Plate Torque maintenance

Tools: Torque wrench

  1. Disconnect the engine starting battery.
  2. Remove the generator fan guard.
  3. Torque each of the drive plate bolts to 33 ft-lb (45 Nm).
  4. Reinstall the generator fan guard and reconnect the battery.
Trailer Wheel Bearings maintenance

Tools: Grease gun

  1. Remove the small rubber plug on the grease cap.
  2. Attach a standard grease gun fitting to the grease zerk fitting.
  3. Pump grease into the fitting until new grease is visible around the nozzle.
  4. Wipe any excess grease from the hub and replace the rubber plug.
AUTO (Remote) Starting of the Generator operation
  1. Perform a manual start of the generator at least once to verify correct operation.
  2. Press the AUTO button; LCD window highlights AUTO in the upper left corner.
  3. Close the main circuit breaker (set to ON/I).
  4. Secure the generator by closing and locking all access doors.
  5. The generator is now ready for remote starting.
Auto Exercise Timer operation

⚠ The controller must be in AUTO mode to run at the programmed time.

  1. Press the PAGE SELECT button until Password appears at the top of the screen.
  2. Press the down arrow to select Date/Time and press ENTER.
  3. Press the down arrow to select Timer1 Repeat and press ENTER; choose the day(s) and press ENTER.
  4. Select Timer1 ON Time and press ENTER; adjust the desired start time.
  5. Select Timer1Duration and press ENTER; set the run duration.
  6. Press PAGE SELECT three times to return to the main menu.
  7. Press the AUTO button to switch modes to automatic.
Auxiliary Fuel Tank Option operation
  1. Shut down the unit and check that the internal tank fuel level is above five percent.
  2. Attach the auxiliary fuel tank fuel lines to the AUXILIARY FUEL INLET and AUXILIARY FUEL OUTLET fittings.
  3. Open the AUXILIARY FUEL INLET and AUXILIARY FUEL OUTLET valves inside the right front door.
Fuel Transfer Pump Option operation
  1. Shut down the unit (not required if external bulk supply is already connected).
  2. Attach the external bulk fuel supply to the FUEL TRANSFER INLET fitting.
  3. Turn on the fuel transfer switch.
Manual Starting of the Generator operation

⚠ CARBON MONOXIDE: USING A GENERATOR INDOORS CAN KILL YOU IN MINUTES!

  1. Move the control ON/OFF toggle switch to the CONTROL ON/I position.
  2. LCD window indicates MAN mode and Ready; Ready/Manual LED is lit.
  3. Press the green ENGINE START button.
  4. Prestart (Preheat) screen is displayed with a countdown from 20 seconds to zero.
  5. Starting screen is displayed; the engine cranks and starts running.
  6. Running screen displays.
  7. LCD toggles between Generator Display Screen and Engine Display Screen.
  8. If engine does not start, controller pauses 15 seconds and makes two more attempts (three total).
  9. If no start after three cycles, LCD shows SD Start Fail; wait two minutes and press FAULT RESET.
  10. Engine speeds up to a constant 1800 rpm.
  11. Check for excessive noise or vibration and coolant, oil or fuel leaks before applying loads.
  12. Check AC output voltage; fine adjust with the fine voltage adjustment screw if needed.
  13. Check frequency reads approximately 60 Hz with no loads.
  14. Switch main circuit breaker ON, then convenience outlet breakers as needed.
Shutting Down the Generator operation

⚠ If the unit does not shut down within 15 seconds, a Stop Fail alarm is displayed.

  1. Open all circuit breakers to remove loads from the generator.
  2. Let the engine run approximately five minutes to allow it to cool down.
  3. Push the red ENGINE STOP button; a 15 second Stop Value timer starts.
  4. Move the CONTROL ON/OFF toggle switch to the CONTROL OFF/O position.
Towing the Trailer operation
  1. Use the jack to raise or lower the trailer onto the hitch; lock the hitch coupling.
  2. Attach the safety chains or cables to the vehicle and raise the jack foot completely.
  3. Connect trailer wiring; check stop and signal lights.
  4. Make sure all doors are properly latched.
  5. Check trailer tire inflation.
  6. Check the wheel lugs and tighten or replace any loose or missing.
  7. Limit highway towing speed to 45 mph (72 km/h).

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
Cam lock connectionsL1 - Black, L2 - Red, L3 - Blue, N (Neutral) - White, G (Ground) - GreenSeries 16 taper nose 400A, 600V cam locks; make all connections to one side only
1203Low DeltaT1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12Dedicated 12 lead generators option
120/208Vthree phaseLow WyeLink / Reconnect Board
120/240Vsingle phaseZig Zag4 position phase switch option
120/240Vthree phaseDelta4 position phase switch option
208/1203Link board attached in 208 VOLT 3Ø position (upper position)T1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12Shorting (link) board upper position
208/1203Low WyeT1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12Dedicated 12 lead generators option
240/1201Low Zig ZagT1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12Dedicated 12 lead generators option
240/1203High DeltaT1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12Dedicated 12 lead generators option
277/480Vthree phaseHigh WyeLink / Reconnect Board
480/2401High Zig ZagT1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12Dedicated 12 lead generators option
480/2773High WyeT1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12Dedicated 12 lead generators option
480/2773Link board attached in 480 VOLT 3Ø position (lower position)T1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12Shorting (link) board lower position

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the John Deere 6090 family

99
Part #DescriptionCategory
AT387574ALTERNATORAlternator
RE500226ALTERNATORAlternator
RE551447ALTERNATORAlternator
RE551448ALTERNATORAlternator
RE558676ALTERNATORAlternator
RE65414ALTERNATORAlternator
SE501838ALTERNATOR (REMAN FOR AT387574) (24V, 100A) (3152)Alternator
SE502563ALTERNATORAlternator
4UA1015 Relay I/O BoardBattery
DZ118761FAN BELTBelt
DZ118828FAN BELTBelt
DZ118995FAN BELTBelt
R519476FAN BELTBelt
T428848FAN BELTBelt
SE501759CONNECTING ROD (REMAN FOR DZ122131)Connecting rod
RM100131CONTROLLERController
SE502800CONTROLLERController
SE501747CYLINDER HEADCylinder head
RG13813Location of Engine Serial Number PlateEngine identification
RG13814Engine Serial Number PlateEngine identification
RG13820Option Code LabelEngine identification
RG14799Engine Serial Number PlateEngine identification
AR44402Valve Stem LubricantFluid
AR54749Soap LubricantFluid
DZ110558SECONDARY FUEL FILTERFuel filter
DZ112918SECONDARY FUEL FILTERFuel filter
PFF51674Secondary Fuel Element (OEM: RE506428)Fuel filter
PFF5551Primary & Secondary Fuel Kit (OEM: RE525523, RE527961)Fuel filter
RE520906PRIMARY FUEL FILTERFuel filter
RE525523Fuel filterFuel filter
RE527961FUEL FILTERFuel filter
RE539465PRIMARY FUEL FILTERFuel filter
SE501947FUEL INJECTION NOZZLE (REMAN FOR DZ100221)Fuel injection nozzle
TY6299PERMATEX AVIATION (Form-A-Gasket No. 3), 227 g (8 oz) containerGasket
SE501948FUEL INJECTION NOZZLEInjector
DZ118283OIL FILTEROil filter
RE509672OIL FILTEROil filter
RE530346OCV FILTEROil filter
4067CPuck model 4067C lagoon boat, powered by a 280-kW (375-hp) PowerTech Plus 9.0L engineService part / kit
51048Pâte LOCTITE Moly PasteService part / kit
A34471UN—11OCT88Service part / kit
APM303Control PanelService part / kit
AR31790Adhésif plastique SCOTCH-GRIP EC1099Service part / kit
CB125100-200Coolant heater, 2500W, 120VService part / kit
CB125110-200Coolant heater, HotStart, 2500W, 120VService part / kit
CTM106819Application ListService part / kit
CTM3859.0 L Diesel Engines — Level 14 Electronic Fuel System with Denso HPCRService part / kit
CTM67OEM Engine AccessoriesService part / kit
D-292865Battery charger, 120/240V, 5.1/3AService part / kit
D17005BRflexible cylinder honeService part / kit
D17006BRhoneService part / kit
DSAB45549Litho in U.S.A. (10-07)Service part / kit
DZ113609SHORT BLOCK ASSEMBLYService part / kit
DZ114640DIESEL EXHAUST FLUID (DEF) DOSING UNIT FILTERService part / kit
DZ114695DEF TANK INLET SCREENService part / kit
DZ121189SHORT BLOCK ASSEMBLYService part / kit
DZ121193SHORT BLOCK ASSEMBLYService part / kit
DZ124403DIESEL EXHAUST FLUID INLINE FILTERService part / kit
GM106699-SBattery (Kohler)Service part / kit
JDE1963Collier-compresseurService part / kit
JDE93Pince à segmentService part / kit
JRG10040Front right lifting lugService part / kit
JRG10059Rear left lifting lugService part / kit
JRG23Engine lifting crossbarService part / kit
M3227CanopyService part / kit
PT506Composé NEVER-SEEZ - Aérosol de 453 gService part / kit
PT569Composé NEVER-SEEZ - À appliquer au pinceau, 227 gService part / kit
R518277CRANKSHAFT PULLEYService part / kit
R527478CRANKSHAFT PULLEYService part / kit
RE520465TORSIONAL DAMPERService part / kit
RE537960TORSIONAL DAMPERService part / kit
RE57604TORSIONAL DAMPERService part / kit
SE501748CONNECTING ROD (REMAN FOR DZ122131)Service part / kit
SE502544CONNECTING RODService part / kit
SE502847COMPLETE BLOCK ASSEMBLYService part / kit
TS203AcidService part / kit
TS204Battery ExplosionsService part / kit
TS271Avoid Hot PartsService part / kit
TS677Install Fan GuardsService part / kit
TY15941LOCTITE® 620Service part / kit
TY15969LOCTITE 609 Retaining Compound — 50 ml bottleService part / kit
TY9370Composé de blocage et d'étanchéité pour filetages LOCTITE 242 (résistance moyenne) (bleu) - Tube de 6 mlService part / kit
TY9374LOCTITE 592 Pipe Sealant with TEFLON (white), 6 mL (0.2 oz) tubeService part / kit
TY9375LOCTITE 592 Pipe Sealant with TEFLON, 50 mL (1.7 oz) tubeService part / kit
SE501228WATER PUMP (REMAN FOR RE530194)Pump
SE501922FUEL INJECTION PUMP (REMAN FOR RE571640)Pump
SE502545WATER PUMPPump
SE502546OIL PUMPPump
TY43512Composé de blocage et d'étanchéité pour filetages LOCTITE 242 (résistance moyenne) (bleu) - Bouteille de 50 mlSeal
DZ118217Cam Sensor Bushing DZ118217Sensor
RE506103STARTERStarter
RE529661STARTERStarter
RE549230STARTERStarter
RE556999STARTERStarter
RE564633STARTERStarter
SE501866STARTER (REMAN FOR RE506103) (24 V)Starter
SE502823STARTERStarter
SE502374TURBOCHARGERTurbocharger
SE502547TURBOCHARGERTurbocharger

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Aftermarket parts that fit this engine

4

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Common questions

What is the displacement of the John Deere RG6090HF485?

The John Deere RG6090HF485 has a displacement of 9.0 liters with 6 cylinders.

Which generators use the John Deere RG6090HF485 engine?

The John Deere RG6090HF485 powers 3 generator set(s), including Generac MMG320, Magnum MMG320, Magnum MMG320 Super Start.

What is a common problem with the John Deere RG6090HF485 engine?

A commonly reported issue on generators using the John Deere RG6090HF485 is: WrnMaintenance — The period for servicing is set by the WrnMaintenance setpoint. The protection comes active if the running hours of the engine reach this value..