Common problems

5
  • No AC output.
    Cause: 1. Generator is overloaded. 2. Inverter module is overheated. 3. Short circuit in electrical device. 4. Defective inverter assembly.
    Fix: 1. Disconnect all loads. Shut down generator to reset module. Reduce loads, restart generator. 2. Verify service door is ON. Let cool 15 minutes by running engine without AC output. Press and hold Reset button on control panel, restart generator. 3. Verify condition of extension cords and items being powered. Press and hold Reset button on control panel. 4. Contact IASD.
  • Fuel leaks from drain hoses.
    Cause: 1. Carburetor drain in bowl is not closed.
    Fix: 1. Turn valve clockwise to close.
  • Engine won't start.
    Cause: 1. Dial turned off. 2. Out of fuel. 3. Defective spark plug. 4. Plugged fuel filter. 5. Defective or stuck Dial assembly. 6. Incorrect engine oil level. 7. Defective ignition coil. 8. Carb is flooded. 9. Throttle plate closed.
    Fix: 1. Turn on Dial. 2. Fill fuel tank. 3. Replace spark plug. 4. Replace fuel and fuel filter. 5. Contact IASD. 6. Check/fill engine oil. 7. Contact IASD. 8. Drain carb. 9. Open throttle plate (push toward back of unit).
  • Engine will not start; or starts and runs rough.*
    Cause: 1. Choke is stuck or left on. 2. Dirty or clogged air filter. 3. Defective or dirty spark plug. 4. Dirty fuel filter. 5. Dirty or gummed up carburetor. 6. Unit not warmed up. 7. Spark arrestor clogged.
    Fix: 1. Turn choke off. 2. Clean or replace air filter. 3. Replace spark plug. 4. Replace fuel and fuel filter. 5. Clean carburetor. 6. Gradually adjust Dial and reduce choke until engine runs smoothly in RUN position. 7. Clean spark arrestor.
  • Engine starts, then shuts down.
    Cause: 1. Out of fuel. 2. Incorrect engine oil level. 3. Contaminated fuel. 4. Defective low oil level switch.
    Fix: 1. Fill fuel tank. 2. Check engine oil level. 3. Contact IASD. 4. Contact IASD.

Compiled from service & troubleshooting documentation across every generator set that uses the Generac GP3300i.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filter011948300 hr Amazon eBay
Fuel filterReplace fuel filter as needed300 hr
Oil filterChange oil filter every 300 hours or annually300 hr
BatteryNot explicitly stated in the document
Belt
CoolantNot explicitly stated in the document300 hr
Coolant filter
OilAt Each Use, Every 100 Hours or Every 6 Months0.6 L100 hr
Spark plugCheck/replace crankcase breather hose, check/fittings/fasteners, inspect valve clearance and adjust if necessary after first 50 hours of operation and every 300 hours thereafter0K95530157300 hr Amazon eBay

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service intervals

11
ItemActionHoursMonthsNotes
Engine oil levelInspect8 hrPrior to each use or every 8 hours of operation
Valve clearanceCheck50 hrFirst service — Check and adjust if necessary after first 50 hours of operation and every 300 hours thereafter
Air FilterClean100 hr6 moEvery 100 Hours or Every 6 Months
Engine OilChange100 hr6 moFirst service — Every 100 Hours or Every 6 Months
Muffler ScreenClean100 hr6 moEvery 100 Hours or Every 6 Months
Spark arrestorClean100 hr6 moMuffler Screen; Clean/Replace Spark Arrestor; inspect and clean screen every 100 hours or six months
Crankcase breather hoseCheck300 hr12 moCheck/Replace
Fittings/fastenersCheck300 hr12 moTo be performed by an IASD
Fuel filterReplace300 hr12 moTo be performed by an IASD
Spark PlugReplace300 hr12 moEvery 300 Hours or Every Year
Valve ClearanceAdjust300 hr12 moEvery 300 Hours or Every Year

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

42
TypeItemValueUnitCondition
GapSpark plug gap0.024-0.028in
GapSpark plug gap0.6-0.7mm
ResistanceExciter Windings - GP1800 (alt 0H8255/0J0819)2.53Ohms
ResistanceExciter Windings - GP3250 (alt 0H2626/0H3578)1.72Ohms
ResistanceExciter Windings - GP5500/GP/LP5500 (alt 0G9769/0J8363)2.81Ohms
ResistanceExciter Windings - GP6500E (alt 0H9920/0K1291)2.9 ± 10%Ohms
ResistanceExciter Windings - GP7500E DF-CO (alt A0001920613/A0000121536)1.928Ohms
ResistanceExciter Windings - GP8000E COSTCO (alt 0J8438/0K9791)1.626Ohms
ResistanceExciter Windings - LP3250 (alt 0J2561/0J6032)2Ohms
ResistancePower Windings - GP1800 (alt 0H8255/0J0819)0.798Ohms
ResistancePower Windings - GP3250 (alt 0H2626/0H3578)0.62Ohms
ResistancePower Windings - GP5500/GP/LP5500 (alt 0G9769/0J8363)0.681Ohms
ResistancePower Windings - GP6500E (alt 0H9920/0K1291)0.6 ± 10%Ohms
ResistancePower Windings - GP7500E (alt 0J1927/0K8981)1.62Ohms
ResistancePower Windings - GP7500E DF-CO (alt A0001920613/A0000121536)0.491Ohms
ResistancePower Windings - GP8000E COSTCO (alt 0J8438/0K9791)0.471Ohms
ResistancePower Windings - LP3250 (alt 0J2561/0J6032)0.63Ohms
ResistanceRotor Windings - GP1800 (alt 0H8255/0J0819)29.4Ohms
ResistanceRotor Windings - GP3250 (alt 0H2626/0H3578)31Ohms
ResistanceRotor Windings - GP5500/GP/LP5500 (alt 0G9769/0J8363)61.48Ohms
ResistanceRotor Windings - GP6500E (alt 0H9920/0K1291)69 ± 10%Ohms
ResistanceRotor Windings - GP7500E (alt 0J1927/0K8981)58.8Ohms
ResistanceRotor Windings - GP7500E DF-CO (alt A0001920613/A0000121536)52.42Ohms
ResistanceRotor Windings - GP8000E COSTCO (alt 0J8438/0K9791)52.17Ohms
ResistanceRotor Windings - LP3250 (alt 0J2561/0J6032)58Ohms
SpeedNo-load AC frequency62.0-62.5hertzrunning adjustment, no-load
TorqueGovernor Lever Clamp Bolt110in-lbs (12.4 Nm)
TorqueGovernor Lever Clamp Bolt70in-lbs (8 Nm)
TorqueRocker Arm Jam Nut14ft-lbs (19 Nm)
TorqueRocker Arm Jam Nut6-9ft-lbs (8-12 Nm)
TorqueRocker Arm Jam Nut7ft-lbs (9.4 Nm)
TorqueRocker Arm Jam Nut9-12ft-lbs (12-16 Nm)
Valve clearanceExhaust Valve Clearance0.004-0.006in (0.01-0.015 mm)
Valve clearanceExhaust Valve Clearance0.0059in (0.015 mm)
Valve clearanceExhaust Valve Clearance0.006 ± 0.001in (0.15 ± 0.02 mm)
Valve clearanceExhaust valve clearance0.10 ± 0.02mmcold
Valve clearanceIntake Valve Clearance0.002-0.004in (0.005-0.01 mm)
Valve clearanceIntake Valve Clearance0.0039in (0.01 mm)
Valve clearanceIntake Valve Clearance0.004 ± 0.001in (0.1 ± 0.02 mm)
Valve clearanceIntake valve clearance0.10 ± 0.02mmcold
Valve clearanceValve Clearance0.003-0.005in (0.0076-0.0127 mm)
Valve clearanceValve Clearance0.005-0.007in (0.013-0.017 mm)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Engine oil10W-30 / SAE 300.6 LRecommended Oil 10W-30 / SAE 30; Oil Capacity 0.6 qt (0.6 L); Lubrication Method: Splash
Engine oilSAE 30, 10W-30, Synthetic 5W-300.6 LMulti-viscosity options per ambient temperature
Engine oilSAE 30, 10W-30, or Synthetic 5W-300.6 LUse petroleum based oil (supplied) for engine break-in before using synthetic oil
FuelUnleaded4.3 L1.14 U.S. gallons fuel capacity
FuelUnleaded gasoline, minimum 87 octane/87 AKI (91 RON), up to 10% ethanol acceptable; do not use E854.3 LDo not use a gas oil mix; stabilize fuel prior to storage

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

1
CodeNameMeaningSeverityAction
Red Short FlashCO Module - Red Short FlashElevated level of CO in the area; module is functioning properly and protecting operatorsShutdownGenerator shuts down; module is functioning as intended

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Test 20 - Check Spark Plugs / Test 23 - Check Valve Adjustment adjustment

Tools: feeler gauge, crow foot wrench

  1. Adjust valve clearance with engine at room temperature
  2. Position piston at TDC of compression stroke (both valves closed), or set intake/exhaust valve fully open method
  3. Loosen rocker arm jam nut; turn pivot ball stud while checking clearance with a feeler gauge
  4. When clearance is correct, hold pivot ball stud and tighten rocker arm jam nut to specified torque with a crow foot wrench
  5. Recheck valve clearance to make sure it did not change
  6. Install rocker arm cover with a new gasket
Test 27 - Check / Adjust Governor adjustment

Tools: AC frequency meter

  1. Loosen governor clamp bolt
  2. Hold governor lever at wide open throttle position
  3. Rotate governor shaft counterclockwise (389/208/196cc) or clockwise (410cc) as far as it will go
  4. Tighten governor lever clamp bolt to 110 in-lbs (389/208/196cc) or 70 in-lbs (410cc)
  5. Turn speed adjustment screw counterclockwise three full turns to avoid overspeed
  6. Start engine and let warm up under no-load
  7. Connect AC frequency meter; no-load frequency should be 62.0-62.5 hertz
  8. Turn speed adjust screw until frequency/RPM is within limits
  9. Apply removable Loctite (Loctite 241) to speed adjust screw threads
Test 41 - CO Module Verification Test diagnostic

⚠ Do NOT insert the drill bit into the LED holes; damage to the LEDs will occur

Tools: 3/64 inch drill bit

  1. Do not install CO badging (decal) prior to performing this test
  2. Run generator under normal operation with no CO module notifications for a minimum of 65 seconds
  3. With generator running, insert blunt end of a 3/64 inch drill bit into test switch hole
  4. Hold the drill bit against the mounting panel until notification LEDs appear and generator shuts off
  5. Successful pin test shows both LEDs on solid (not blinking)
Remove Contents from Carton installation
  1. Open carton completely by cutting each corner from top to bottom.
  2. Remove and verify carton contents prior to assembly.
  3. Call Generac Customer Service with unit model and serial number for any missing carton contents.
  4. Record model, serial number, and date of purchase on front cover of this manual.
Add Engine Oil maintenance

⚠ Engine damage. Verify proper type and quantity of engine oil prior to starting engine.

Tools: funnel

  1. Place generator on a level surface.
  2. Remove screws and side cover.
  3. Remove oil fill cap/dipstick and wipe dipstick clean.
  4. Insert funnel into oil fill opening and add recommended engine oil.
  5. Insert dipstick without screwing it in; verify oil level is within safe operating range.
  6. Install oil fill cap/dipstick and hand-tighten.
  7. Install side panel and screws.
Change Engine Oil maintenance

⚠ Risk of burns. Allow engine to cool before draining oil or coolant.

⚠ Accidental start-up. Disconnect spark plug wires when working on unit.

Tools: funnel, container

  1. Place generator on a level surface.
  2. Remove screws, side cover and spark plug cover.
  3. Disconnect the spark plug wire and place where it cannot contact spark plug.
  4. Clean area around oil fill and oil drain plug.
  5. Remove oil fill cap/dipstick and wipe dipstick clean.
  6. Tip unit and drain oil completely into a suitable container.
  7. Install oil drain plug and tighten securely.
  8. Insert funnel and add recommended engine oil.
  9. Verify oil level is within safe operating range.
  10. Install oil fill cap/dipstick and hand-tighten.
  11. Wipe up any spilled oil.
  12. Install side panel, screws, and spark plug cover.
  13. Properly dispose of oil in accordance with all applicable regulations.
Inspect Spark Arrestor Screen maintenance

⚠ Hot Surfaces. Do not touch hot surfaces. Keep machine away from combustibles during use.

  1. Remove the clamp to remove retainer.
  2. Slide spark arrestor screens out from the muffler outlet tube.
  3. Inspect screens and replace if torn, perforated or otherwise damaged; clean with a commercial solvent if not damaged.
  4. Replace the screens, retainer, and secure with clamp.
Prepare Fuel System/Engine for Storage maintenance

⚠ Vision Loss. Eye protection is required to avoid spray from spark plug hole when cranking engine.

  1. Loosen screw (A) and drain fuel from carburetor.
  2. Change engine oil.
  3. Remove spark plug.
  4. Pour tablespoon (5-10cc) of clean engine oil or spray a suitable fogging agent into cylinder.
  5. Pull starter recoil several times to distribute oil in cylinder.
  6. Install spark plug.
  7. Pull recoil slowly until resistance is felt to close valves; gently release recoil.
Service Air Filter maintenance
  1. Unscrew bolt (A) and remove air filter cover.
  2. Wash filter (B) in soapy water.
  3. Squeeze dry in clean cloth (DO NOT TWIST).
  4. Clean air filter cover before installation.
  5. Replace side cover and screws.
Service Spark Plug maintenance

Tools: feeler gauge, spark plug wrench

  1. Remove spark plug cover and disconnect spark plug wire.
  2. Clean area around spark plug.
  3. Remove and inspect spark plug.
  4. Inspect electrode gap with feeler gauge and reset spark plug gap to 0.6 - 0.7 mm (0.024 - 0.028 in).
  5. Install spark plug finger tight, and tighten an additional 3/8 to 1/2 turn using spark plug wrench.
Generator Shut Down operation

⚠ Equipment and property damage. Disconnect electrical loads prior to starting or stopping unit.

  1. Shut off all loads and unplug electrical loads from generator panel receptacles.
  2. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator.
  3. Rotate PowerDial to OFF (3).
Starting Hot Engines operation
  1. Turn PowerDial from OFF to RUN to open the fuel valve and permit starting.
  2. Firmly grasp recoil handle and pull slowly until increased resistance is felt. Pull rapidly up and away.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the oil capacity of the Generac GP3300i?

The Generac GP3300i engine has an oil capacity of 0.6 liters.

What is the displacement of the Generac GP3300i?

The Generac GP3300i has a displacement of 0.149 liters with 1 cylinders.

Which generators use the Generac GP3300i engine?

The Generac GP3300i powers 1 generator set(s), including Generac GP3300.

How often should you change the oil in the Generac GP3300i?

The Generac GP3300i oil change interval is every 100 hours.

What is a common problem with the Generac GP3300i engine?

A commonly reported issue on generators using the Generac GP3300i is: No AC output.. Cause: 1. Generator is overloaded. 2. Inverter module is overheated. 3. Short circuit in electrical device. 4. Defective inverter assembly.. Fix: 1. Disconnect all loads. Shut down generator to reset module. Reduce loads, restart generator. 2. Verify service door is ON. Let cool 15 minutes by running engine without AC output. Press and hold Reset button on control panel, restart generator. 3. Verify condition of extension cords and items being powered. Press and hold Reset button on control panel. 4. Contact IASD..