The Generac G-Force™ Série 800 is a 0.82 L engine. It powers generator sets from Generac, including the G0072100. It holds 2.1 L (0.6 gal) of oil.
Also known as: G-Force™ série 800, Generac G-Force™ Série 800
Part of the Generac G-Force 800 engine family — 3 variants share parts & fitment.
| Oil capacity | 2.1 L |
|---|---|
| Displacement | 0.816 L |
Compiled from service & troubleshooting documentation across every generator set that uses the Generac G-Force™ Série 800.
| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Aceite del motor | Change | 25 hr | First service — Después del período de asentamiento de 25 horas, se recomienda utilizar el aceite 5W-20 propiedad de Generac para uso continuo. | |
| Engine oil | Change | 25 hr | First service — After the 25 hour break-in period, use Generac 5W-20 GEO for continuous use | |
| Huile moteur et filtre à huile | Change | 25 hr | First service — Après les premières 25 heures de marche | |
| Jeu des soupapes | Adjust | 25 hr | First service — Après les premières 25 heures de marche; puis toutes les 400 heures | |
| Battery condition | Check | 200 hr | 24 mo | Schedule A. |
| Óleo lubrificante e filtro de óleo | Change | 200 hr | 24 mo | First service — Trocar após as primeiras 25 horas; Programação A (2 anos ou 200 h); em clima frio (<4,4 °C) ou quente contínuo (>29,4 °C) anualmente ou 100 h |
| Aceite del motor y filtro de aceite | Replace | 400 hr | 48 mo | First service — Programa B: cada cuatro años o 400 horas. |
| Bujía(s) | Replace | 400 hr | 48 mo | Programa B: cada cuatro años o 400 horas. |
| Engine air filter | Replace | 400 hr | 48 mo | Schedule B. Emissions-critical. |
| Engine oil and oil filter | Change | 400 hr | 48 mo | First service — Schedule B. |
| Filtro de aire del motor | Replace | 400 hr | 48 mo | Programa B: cada cuatro años o 400 horas. |
| Filtro de ar do motor | Replace | 400 hr | 48 mo | Programação B (4 anos ou 400 h) |
| Folga da válvula | Adjust | 400 hr | 48 mo | First service — Inspecionar/ajustar após as primeiras 25 h e depois a cada 400 h; Programação B; exclui 14/18 kW com motor 816 cc |
| Separación de la válvula | Adjust | 400 hr | 48 mo | First service — Programa B. Inspeccione y ajuste después de las primeras 25 horas y luego cada 400 horas. No necesario en unidades 14/18 kW con motor 816 cc. |
| Spark plug(s) | Replace | 400 hr | 48 mo | Schedule B. Emissions-critical. |
| Valve clearance | Adjust | 400 hr | 48 mo | First service — Schedule B; inspect/adjust valve clearance after first 25 hours of operation, then at 400 hour intervals. Where applicable; excludes units with hydraulic lifters (14 or 18 kW with 816cc engine). |
| Valve clearance | Inspect | 400 hr | 48 mo | First service — Where applicable; excludes units with hydraulic lifters (14 kW and 18 kW with 816cc engine). |
| Vela(s) de ignição | Replace | 400 hr | 48 mo | Programação B (4 anos ou 400 h) |
| Bateria | Check | 12 mo | Estado da bateria; todos os anos | |
| Condición de la batería | Inspect | 12 mo | Anualmente (revisión de batería y carga). | |
| Enclosure louvers | Inspect | 12 mo | Remove any shrubs or tall grasses within 3 ft (0.91 m) of intake/discharge louvers; clean accumulated debris inside enclosure. | |
| Fuel system | Test | 12 mo | Perform fuel system leak test from supply to regulator. | |
| Lines and connections (fuel and oil) | Inspect | 12 mo | Inspect for fuel or oil leaks. | |
| Prueba de fugas del sistema de combustible | Test | 12 mo | Anualmente. | |
| Sistema de combustível | Test | 12 mo | Teste de vazamento; todos os anos | |
| Water intrusion | Inspect | 12 mo | Verify water sprinklers, roof run-off, downspouts and sump pump discharges are directed away from generator enclosure. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Gap | Folga da vela de ignição | 0,020 | pol | |
| Gap | Folga da vela de ignição | 0,040 | pol | |
| Gap | Folga da vela de ignição | 0,508 | mm | |
| Gap | Folga da vela de ignição | 1,02 | mm | |
| Gap | Separación de las bujías | 0.508 | mm (0.020 pulg.) | |
| Gap | Separación de las bujías | 1.02 | mm (0.040 pulg.) | |
| Gap | Spark plug gap | 0.020 in (0.508 mm) | in (mm) | |
| Gap | Spark plug gap | 0.040 in (1.02 mm) | in (mm) | |
| Gap | Spark plug gap (10 kW) | 0.020 | in (0.508 mm) | |
| Gap | Spark plug gap (14-24 kW) | 0.040 | in (1.02 mm) | |
| Gap | Écartement de bougie | 0,508 | mm (0,020 po) | |
| Gap | Écartement de bougie | 1,02 | mm (0,040 po) | |
| Other | Cold Smart Start fixed temperature | 20 F (-7 C) | F (C) | 22-26 kW |
| Other | Cold Smart Start fixed temperature | 50 F (10 C) | F (C) | 10-20 kW |
| Other | Fusível do painel de controle | 7,5 | A | |
| Other | Ordem de partida (10 kW) | 15 s de arranque, 7 s de repouso, seguidos por quatro ciclos adicionais de 7 s de arranque e 7 s de repouso | cinco ciclos de manivela | |
| Other | Ordem de partida (14 a 24 kW) | 16 s de arranque, 7 s de repouso, 16 s de arranque, 7 s de repouso, seguidos por três ciclos adicionais de 7 s de arranque e 7 s de repouso | cinco ciclos de manivela | |
| Other | Perda de potência do motor por altitude | 3,5 | % a cada 304,8 m (1.000 pés) acima do nível do mar | |
| Other | Perda de potência do motor por temperatura | 1 | % a cada 6 °C (10 °F) acima de 15 °C (60 °F) | |
| Other | Redução de classificação GN vs PL | 10 a 20 | % | |
| Other | Tamanho mínimo de tanque de PL ao converter de GN | 946 | L (250 gal) | |
| Pressure | Fuel pressure at regulator, LP gas | 10-12 in water column (2.49-2.99 kPa) | in water column (kPa) | |
| Pressure | Fuel pressure at regulator, NG | 3.5-7.0 in water column (0.87-1.74 kPa) | in water column (kPa) | |
| Pressure | Fuel pressure to regulator (LP) | 10-12 | in water column (2.49-2.99 kPa) | |
| Pressure | Fuel pressure to regulator (NG) | 3.5-7.0 | in water column (0.87-1.74 kPa) | |
| Pressure | LP gas required fuel pressure at generator fuel inlet | 10–12 in water column (2.49–2.99 kPa) | in water column | |
| Pressure | Natural gas required fuel pressure at generator fuel inlet | 3.5–7.0 in water column (0.87–1.74 kPa) | in water column | |
| Pressure | Presión del combustible (GN) | 0.87 a 1.74 | kPa (3.5 a 7.0 pulg. de columna de agua) | |
| Pressure | Presión del combustible (PL) | 2.49 a 2.99 | kPa (10 a 12 pulg. de columna de agua) | |
| Pressure | Pression de carburant GN à l’entrée du vapo-détendeur | 0,87 à 1,74 | kPa (3,5 à 7,0 poH2O) | GN |
| Pressure | Pression de carburant GPL à l’entrée du vapo-détendeur | 2,49 à 2,99 | kPa (10 à 12 poH2O) | GPL |
| Pressure | Pressão do combustível (GN) para o regulador | 0,87–1,74 | kPa | gás natural |
| Pressure | Pressão do combustível (GN) para o regulador | 3,5–7,0 | pol de coluna de água | gás natural |
| Pressure | Pressão do combustível (PL) para o regulador | 10–12 | pol de coluna de água | gás PL |
| Pressure | Pressão do combustível (PL) para o regulador | 2,49–2,99 | kPa | gás PL |
| Speed | Duração do ciclo de exercício | 5 | minutos | extensão do tempo de exercício |
| Speed | Frecuencia de salida del generador (E1 a E2) | 59.5 a 60.5 | Hz | con el generador funcionando |
| Speed | Generator output frequency (E1-E2) | 59.5–60.5 | Hz | during electrical checks |
| Temperature | Cold weather kit recommended below | 32 | F (0 C) | |
| Temperature | Faixa de operação normal | -20 a 122 | °F | testado conforme UL 2200 |
| Temperature | Faixa de operação normal | -29 a 50 | °C | testado conforme UL 2200 |
| Temperature | Normal operating range (tested to UL 2200) | -20 F to 122 F (-29 C to 50 C) | F (C) | |
| Temperature | Ponto de ajuste Cold Smart Start | -7 | °C | 22/24 kW |
| Temperature | Ponto de ajuste Cold Smart Start | 10 | °C | 10 kW a 20 kW |
| Temperature | Ponto de ajuste Cold Smart Start | 20 | °F | 22/24 kW |
| Temperature | Ponto de ajuste Cold Smart Start | 50 | °F | 10 kW a 20 kW |
| Temperature | Rango de funcionamiento normal (UL 2200) | -29 a 50 | °C (20 a 122 °F) | |
| Temperature | Rated operating temperature range | -20 F to 122 F | (-29 C to 50 C) | per UL 2200 test |
| Torque | Barra colectora de neutro | 2.26 | Nm (20 lb-pulg.) | 10 a 14 AWG |
| Torque | Barra colectora de neutro | 2.82 | Nm (25 lb-pulg.) | 8 AWG |
| Torque | Barra colectora de neutro | 3.95 | Nm (35 lb-pulg.) | 4 a 6 AWG |
| Torque | Battery cable connections | 70 in-lbs (8 Nm) | in-lbs | |
| Torque | Bougies d’allumage | 25 | Nm (18,4 pi-lb) | |
| Torque | Bujía(s) | 25 | Nm (18.4 lb-pie) | |
| Torque | Cables de la batería (positivo y negativo) | 8 | Nm (70 lb-pulg.) | |
| Torque | Contraporca do braço oscilante | 174 | pol-lb | 20 a 24 kW |
| Torque | Contraporca do braço oscilante | 19,68 | Nm | 20 a 24 kW |
| Torque | Contraporca do braço oscilante | 53 | pol-lb | 10 kW |
| Torque | Contraporca do braço oscilante | 6,0 | Nm | 10 kW |
| Torque | Contratuerca del balancín | 19.68 | Nm (174 lb-pulg.) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | API SJ, SL ou mieux | Changer l'huile chaque année ou toutes les 100 heures par temps froid (< 4,4 °C) ou exploitation continue par temps chaud (> 29,4 °C) | |||
| Engine oil | 5W-20 | Aceite 5W-20 propiedad de Generac para uso continuo, después del período de asentamiento de 25 horas. | |||
| Engine oil | 5W-20 (Generac proprietary) | API Service Class SJ, SL, or better | 1.03 L | Oil capacity including filter. Use for continuous use after the 25 hour break-in period; specifically formulated for gaseous powered Generac generators. Do not use special additives. Change every year or 100 hours in cold weather (below 40 F) or continuous hot weather (above 85 F). | |
| Engine oil | 5W-30 | Aceite orgánico 5W-30 prellenado de fábrica. | |||
| Engine oil | 5W-30 (factory fill) / 5W-20 GEO (continuous) | Generac proprietary gaseous engine oil (GEO) | Unit comes filled with 5W-30 organic oil; after 25 hour break-in use 5W-20 GEO | ||
| Engine oil | Generac 5W-20 exclusive | API SJ, SL ou mieux | Après la période de rodage de 25 heures et à chaque intervalle; spécialement formulée pour les génératrices Generac alimentées au gaz | ||
| Fuel | Gás natural: mínimo 37,26 MJ/m³ (1.000 BTU/pé³); PL: mínimo 93,15 MJ/m³ (2.500 BTU/pé³) | Sistema de combustível de dupla carburação; configurado de fábrica para GN | |||
| Fuel | Gas natural | Contenido de BTU de al menos 37.26 MJ/m3 (1,000 BTU/pie3); presión de suministro 0.87 a 1.74 kPa (3.5 a 7.0 pulg. de columna de agua) en la entrada de combustible | Tamaño mínimo de tanque/medidor debe cubrir el generador a carga completa más todas las cargas de los artefactos. | ||
| Fuel | LP gas (vapor), minimum 2,500 BTUs per ft3 (93.15 megajoules per m3) | Vapor withdrawn liquid propane. | |||
| Fuel | Liquid propane (LP) vapor | BTU content at least 2,500 BTUs per ft3 (93.15 megajoules per m3) | If converting to LP gas from NG, a minimum LP tank size of 250 gal (946 L) is recommended. | ||
| Fuel | Natural gas (NG) | BTU content at least 1,000 BTUs per ft3 (37.26 megajoules per m3) | Unit factory-configured to run on NG. | ||
| Fuel | Natural gas, minimum 1,000 BTUs per ft3 (37.26 megajoules per m3) | Dual fuel carburetion; factory-configured for NG. Minimum LP tank size 250 gal (946 L) if converting to LP. | |||
| Fuel | Natural gas: at least 1,000 BTU/ft3 (37.26 MJ/m3); LP gas: at least 2,500 BTU/ft3 (93.15 MJ/m3) | LP gas should only use a vapor withdrawal system | |||
| Fuel | Propano líquido (vapor) | Contenido de BTU de al menos 93.15 MJ/m3 (2,500 BTU/pie3); presión de suministro 2.49 a 2.99 kPa (10 a 12 pulg. de columna de agua) en la entrada de combustible | 946.0 L (tamaño mínimo de tanque recomendado, 250 gal) | Solo sistema de recuperación de vapor. No conectar a un tanque de propano líquido de 20 o 30 lb (9 o 14 kg). | |
| Other | Água destilada (baterias não lacradas) | Encha apenas com água destilada; NÃO use água comum de torneira | |||
| Other | Solución de bicarbonato de sodio | 454.0 | Agente neutralizante de ácidos para derrames de electrolito de batería. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| BATERÍA BAJA | BATERÍA BAJA | Indicador LED amarillo encendido en cualquier estado. | Warning | Borre la alarma. Navegue hasta BATTERY MENU del MAIN MENU para revisar la batería. Si indica GOOD, comuníquese con un IASD. Si indica CHECK BATTERY, reemplace la batería. |
| BATTERY PROBLEM | Battery Problem | Yellow LED illuminated in any state. | Warning | Contact an IASD. |
| CARGADOR SIN CA | CARGADOR SIN CA | Indicador LED amarillo encendido en cualquier estado. | Warning | Comuníquese con un IASD. |
| CHARGER MISSING AC | Charger Missing AC | Yellow LED illuminated in any state. | Warning | Contact an IASD. |
| CHARGER WARNING | Charger Warning | Yellow LED illuminated in any state. | Warning | Contact an IASD. |
| CONTROLLER FAULT | Controller Fault | Alarm message listed on controller menu. | Shutdown | Contact an IASD. |
| DESCONEXIÓN AUXILIAR | DESCONEXIÓN AUXILIAR | La unidad no arranca. | Shutdown | Coloque los interruptores de desconexión auxiliar en posición CERRADA (I). |
| EMERGENCY STOP | Emergency Stop | Alarm message listed on controller menu. | Shutdown | Check emergency shutdown switch and reset. |
| FUSE PROBLEM | Fuse Problem | Alarm message listed on controller menu. | Shutdown | Check 7.5A controller fuse and replace if blown. |
| HIGH TEMPERATURE | High Engine Temp | Unit shuts down during operation. Red LED. | Shutdown | Inspect ventilation around generator, intake, exhaust, and rear of generator. If no obstructions are present, contact an IASD. |
| INSPECCIONE LA BATERÍA | INSPECCIONE LA BATERÍA | Indicador LED amarillo encendido en cualquier estado. | Warning | Inspeccione la batería. Presione ENTER para borrar. |
| INSPECT BATTERY | Inspecionar a bateria | LED amarelo aceso em qualquer estado. | Info | Inspecione a bateria. Pressione ENTER para apagar. |
| LOW BATTERY | Bateria baixa | LED amarelo aceso em qualquer estado. | Warning | Apague o alarme. Verifique a bateria no BATTERY MENU. Se GOOD, entre em contato com uma IASD. Se CHECK BATTERY, troque a bateria. |
| LOW OIL PRESSURE | Low Oil Pressure | Unit will not start in AUTO with utility loss. Red LED. | Shutdown | Check oil level and add oil as needed. If oil level is correct, contact an IASD. |
| LOW VOLTS REMOVE LOAD | Low Volts Remove Load | Unit will not start in AUTO with utility loss. Red LED. | Shutdown | Clear alarm and remove household loads. Put in AUTO and restart. |
| NOT ACTIVATED | Unit Not Activated | Unit will not start in AUTO with utility loss. No LED. | Info | See Activation section in installation manual. |
| OVERCRANK | Overcrank | Unit will not start in AUTO with utility loss. Red LED. | Shutdown | Verify fuel line shutoff valve is ON. Clear alarm. Start unit in MANUAL. If it does not start or runs rough, contact an IASD. |
| OVERLOAD REMOVE LOAD | Overload Remove Load | Unit shuts down during operation. Red LED. | Shutdown | Clear alarm and remove household loads from generator. Put in AUTO and restart. |
| OVERLOAD WARNING | Aviso de sobrecarga | Aviso de sobrecarga. | Warning | Remova as cargas domésticas do gerador. |
| OVERSPEED | Overspeed | Unit will not start in AUTO with utility loss. Red LED. | Shutdown | Contact an IASD. |
| OVERVOLTAGE | Overvoltage | Unit will not start in AUTO with utility loss. Red LED. | Shutdown | Contact an IASD. |
| PROBLEMA DE BATERÍA | PROBLEMA DE BATERÍA | Indicador LED amarillo encendido en cualquier estado. | Warning | Comuníquese con un IASD. |
| RPM SENSE LOSS | RPM Sense Loss | Unit was running and shut down, attempts to restart. Red LED. | Shutdown | Clear alarm and remove household loads. Put into AUTO and restart. If generator does not start, contact an IASD. |
| SERVICE A | Service Schedule A | Yellow LED illuminated in any state. | Warning | Perform SERVICE A maintenance. Press ENTER to clear. |
| SERVICE B | Service Schedule B | Yellow LED illuminated in any state. | Warning | Perform SERVICE B maintenance. Press ENTER to clear. |
| SHUTDOWN SWITCH | Shutdown Switch | Unit will not start. Flashing red LED. | Shutdown | Check emergency shutdown switches. Set switch(es) to CLOSED (I). Clear alarm. |
| STEPPER OVERCURRENT | Stepper Overcurrent | Unit will not start in AUTO with utility loss. Red LED. | Shutdown | Contact an IASD. |
| UNDERSPEED | Underspeed | Unit will not start in AUTO with utility loss. Red LED. | Shutdown | Contact an IASD. |
| UNDERVOLTAGE | Undervoltage | Unit will not start in AUTO with utility loss. Red LED. | Shutdown | Contact an IASD. |
| USB WARNING | Aviso de USB | Aviso relacionado ao dispositivo USB. | Warning | Tente novamente com USB de melhor qualidade. Os nomes dos ficheiros no USB não podem ter mais de 8 caracteres. |
| WIRING ERROR | Wiring Error | Unit will not start in AUTO with utility loss. Red LED. | Shutdown | Contact an IASD. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
⚠ Risk of Burn. Allow the engine to cool before performing the following procedure.
Tools: feeler gauge, 10 mm wrench, 13 mm wrench, 14 mm wrench, 10 mm hex key
⚠ Risco de queimaduras. Deixe o motor esfriar antes de executar o procedimento.
Tools: Chave de 10 mm, Chave de 13 mm, Chave de 14 mm, Chave sextavada de 10 mm, Calibrador
⚠ Deje que el motor se enfríe antes del procedimiento.
⚠ Desconecte el cable negativo y luego el positivo de la batería.
⚠ No necesario en unidades 14 o 18 kW con motor de 816 cc.
Tools: Llave de 10 mm, Llave de 13 mm, Llave de 14 mm, Llave hexagonal de 10 mm, Galga de espesores
⚠ Risque de brûlure : laisser le moteur refroidir avant d’exécuter la procédure.
⚠ Réglage non requis sur les modèles de 14 ou 18 kW à moteur de 816 cc.
Tools: Clé de 10 mm ou 13 mm, Clé de 14 mm ou clé hexagonale de 10 mm, Jauge d’épaisseur
⚠ La perilla del selector de combustible debe ajustarse al combustible correcto para que el generador funcione correctamente.
⚠ Fuel and vapors are extremely flammable and explosive; no leakage permitted.
⚠ Risco de queimaduras. Deixe o motor esfriar antes de executar o procedimento.
⚠ Partida acidental. Desconecte o cabo negativo da bateria primeiro.
Tools: Calibrador, Chave de soquete, Soquete grande
⚠ Todo el sistema de combustible debe comprobarse desde el suministro al regulador.
Tools: Fluido de detección de fugas de gas no corrosivo
⚠ High voltage is present at transfer switch and terminals.
Tools: Calibrated AC voltmeter, Frequency meter, Manometer
⚠ Do not manually transfer under load.
Tools: Calibrated AC voltmeter, Frequency meter, Manometer
⚠ No transfiera manualmente bajo carga. Desconecte el interruptor de transferencia de todas las fuentes antes de la transferencia manual.
Tools: Voltímetro de CA, Medidor de frecuencia, Manómetro de combustible
⚠ Alto voltaje presente en el interruptor de transferencia y los terminales.
⚠ No continúe hasta que la frecuencia y el voltaje de CA del generador sean correctos y estén dentro de los límites.
Tools: Voltímetro de CA calibrado, Medidor de frecuencia calibrado, Manómetro de combustible
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| Neutral for battery charger | WHITE NEU/00 | Must be connected to keep battery charged whether unit is running or not | ||
| 12 VDC | DC (+) 12 VDC for transfer controls | RED 194 | ||
| 12 VDC | DC (-) common ground wire | BLACK 0 | ||
| 12 VDC | Transfer control signal wire | WHITE 23 | Required if generator is paired with optional Digital Power Management (DPM) smart technology | |
| 120 VAC | Fused 120 VAC for battery charger | BLUE T1 | Must be connected to keep battery charged whether unit is running or not | |
| 240 VAC | Utility dropout and pickup sensing | YELLOW N1 & N2 |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Part # | Description | Category |
|---|---|---|
| 0C8127 | Recommended Air Filter | Air filter |
| 0J8478 | Air Filter | Air filter |
| 0J8478S | Air filter | Air filter |
| A0006487350 | AGM Group BTX20L Battery | Battery |
| G005819-0 | 26R Wet Cell Battery | Battery |
| JN-255000A-J | Fuel filter | Fuel filter |
| 10000014927 | Joint de cache-culbuteurs | Gasket |
| 070185B | OIL FILTER | Oil filter |
| 070185E | Oil Filter | Oil filter |
| 070185ES | Filtre à huile recommandé | Oil filter |
| 0D7178T | Control panel fuse | Service part / kit |
| 0F6148DSRV | Battery Warming Blanket | Service part / kit |
| 0H3421S | 26R Exide battery | Service part / kit |
| 0K8184 | 1 in ball valve | Service part / kit |
| 0K8754 | 3/4 in ball valve | Service part / kit |
| 0L2844 | 1-1/4 in ball valve | Service part / kit |
| 0L2845 | 1-1/2 in ball valve | Service part / kit |
| G005621-0 | Auxiliary Transfer Switch Contact Kit | Service part / kit |
| G007000-1 | Generac Load Manager (50 amp) | Service part / kit |
| G007006-1 | Generac Load Manager (100 amp) | Service part / kit |
| G007009-0 | LTE LP Tank Fuel Level Monitor | Service part / kit |
| G007102-1 | Oil Heater | Service part / kit |
| G007103-2 | Breather Heater | Service part / kit |
| G007211-0 | Battery Heater | Service part / kit |
| G007216-0 | Scheduled Maintenance Kit | Service part / kit |
| G009918-0 | Touch-Up Paint Kit | Service part / kit |
| Q115AF | 15A Single Pole AFCI | Service part / kit |
| Q120AF | 20A Single Pole AFCI | Service part / kit |
| 0G0767A | Spark Plug (RC12YC or equivalent) | Spark plug |
| RC12YC | Recommended Spark Plug | Spark plug |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
The Generac G-Force™ Série 800 engine has an oil capacity of 2.1 liters.
The Generac G-Force™ Série 800 has a displacement of 0.816 liters.
The Generac G-Force™ Série 800 powers 1 generator set(s), including Generac G0072100.
A commonly reported issue on generators using the Generac G-Force™ Série 800 is: Unit will not start in AUTO with utility loss — LED RED. Cause: Check LEDs / screen for alarms.. Fix: Check oil level and add oil as needed. If oil level is correct, contact an IASD..