Home›Engines›Generac 16.0L

Generac 16.0L Engine

The Generac 16.0L is a 16.12 L 6-cylinder turbocharged/aftercooled engine rated at 1800 rpm, producing up to 757 kW. It powers generator sets from Generac, including the MD1000GEM. It holds 48 L (12.7 gal) of oil and 60.2 L (15.9 gal) of coolant.

Also known as: 16.0L, Generac 16.0L

16.12 L
Displacement
6
Cylinders
1800 rpm
Rated speed
757 kW
Gross power

Engine specifications

Oil capacity48.0 L
Coolant capacity60.2 L
Displacement16.12 L
Cylinders6
AspirationTurbocharged/Aftercooled
Rated speed1800 rpm
Gross power757 kW

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filter11" O.D. 7" outletC1993 eBay
Fuel filter0A88290194 eBay
Oil filter0A53990233 eBay $44.00
Belt0A88290584 eBay $275.00
Coolant50/50 mixture of low silicate ethylene glycol base anti-freeze and soft water85.0 L—
OilAPI Classification For Service CC or CD34.81 L—

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service intervals

40
ItemActionHoursMonthsNotes
engine crankcase oil and oil filterChange30 hrFirst service
engine cylinder head boltsOther30 hrFirst service — Retorque after first 30 hours
engine fan beltsInspect30 hrFirst service
engine fan boltsOther30 hrFirst service — Retorque after first 30 hours
injection timingCheck30 hrFirst service
intake/exhaust manifoldsOther30 hrFirst service — Retorque after first 30 hours
valve clearanceAdjust30 hrFirst service — Check/adjust after first 30 hours of operation
wiringInspect30 hrFirst service
exhaust systemInspect120 hr3 moEvery 120 hours or three months
fuel supply systemTest120 hr3 moEvery 120 hours or three months
fuel system and connectionsInspect120 hr3 moEvery 120 hours or every three months, whichever comes first
cooling system thermostatTest1000 hrRemove/test, every 1000 hours
engine DC alternatorInspect1000 hrDisassemble and inspect, every 1000 operating hours
engine mounting bracketsOther1000 hrRetorque, every 1000 hours
engine starterInspect1000 hrDisassemble and inspect, every 1000 hours
fuel injection pumpTest1000 hrRemove/test, every 1000 hours
intake and exhaust manifoldOther1000 hrRetorque, every 1000 hours
oil pan boltsOther1000 hrFirst service — Retorque, every 1000 hours
AC generatorInspect6 mo
all rubber hosesReplace24 moEvery two years
all wiringInspect12 moOnce annually
annunciator panelTest6 moCheck/test
batteryCheck6 mo
battery and cablesInspect30 hr1 moFirst service — Every month
coolant levelCheck1 moEvery month
cooling systemChange24 moDrain, flush, refill, every two years
electrical connectionsCheck6 mo
engine air cleanerOther6 moService
engine compressionCheck6 mo
engine controlsLubricate6 mo
engine coolant levelCheck6 mo
engine cooling system hosesInspect6 mo
engine fan beltsReplace24 moEvery two years
engine fuel filterOther6 moService
engine oil and filterChange6 moOnce every six months
engine oil levelCheck1 moEvery month
engine safety controlsTest6 mo
engine starter operationTest12 moOnce annually
engine valve clearanceCheck12 moOnce annually
fan beltsInspect6 mo

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50/50 mixture of low silicate ethylene glycol base anti-freeze and soft water85.0 LCooling system capacity 22.4 U.S. gallons (85 liters). A high quality rust inhibitor may be added. Always add the recommended 50/50 mixture.
Engine oilSAE 20API Classification For Service CC or CDRecommended for ambient temperature 12°F to 32°F
Engine oilSAE 30API Classification For Service CC or CDRecommended for ambient temperature 32°F to 90°F
Engine oilSAE 40API Classification For Service CC or CD34.81 LRecommended for ambient temperature above 90°F. High quality detergent oil. Crankcase oil capacity 9.2 U.S. gallons.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the oil capacity of the Generac 16.0L?

The Generac 16.0L engine has an oil capacity of 48.0 liters.

What is the displacement of the Generac 16.0L?

The Generac 16.0L has a displacement of 16.12 liters with 6 cylinders.

Which generators use the Generac 16.0L engine?

The Generac 16.0L powers 1 generator set(s), including Generac MD1000GEM.