Cummins/Onan EGMBT (P4500) Engine Engine
The Cummins/Onan EGMBT (P4500) is a 0.34 L engine rated at 3000 rpm. It powers generator sets from Cummins/Onan, including the EGMBT. It holds 1.16 L (0.3 gal) of oil.
Also known as: Cummins Onan EGMBT (P4500)
Engine specifications
| Oil capacity | 1.16 L |
|---|
| Displacement | 0.34 L |
|---|
| Rated speed | 3000 rpm |
|---|
Generator sets powered by this engine
1Cummins/Onan EGMBT
Common problems
8- NO DC OUTPUT
Cause: · Tripped DC circuit breaker
Fix: 1. Disconnect the battery. 2. Reset the circuit breaker. 3. Have the battery tested for shorts and, if necessary, replace the battery. - NO AC OUTPUT
Cause: · Tripped AC circuit breaker
Fix: 1. Remove all loads. 2. Reset the circuit breaker. 3. Check loads for defects and make sure the total load does not exceed the generator set rating. - ENGINE WON'T START
Cause: · Out of fuel · Fuel value closed · Loose spark plug cable · Defective spark plug · Low oil level
Fix: 1. Make sure the fuel tank is full. 2. Make sure the fuel valve is fully open. 3. Make sure the spark plug cable is connected. 4. Remove and clean the spark plug; replace it if necessary. 5. Check the oil level and add oil as necessary. - ENGINE SURGES
Cause: · Loose spark plug cable · Faulty spark plug · Generator set not level · Dirty fuel strainer
Fix: 1. Make sure the spark plug cable is properly connected or have it serviced, if damaged. 2. Remove and clean or replace the spark plug. 3. Make sure the generator set is on a level surface. 4. Check the fuel strainer and clean if necesary. - ENGINE STOPS
Cause: · Out of fuel · Low oil level
Fix: 1. Make sure the fuel tank is full. 2. Check the oil level and add oil as necessary. - ENGINE DOES NOT CRANK (ELECTRIC START)
Cause: · Low battery · Bad battery connection - ENGINE CRANKS SLOWLY (ELECTRIC START)
Cause: · Low battery · Bad battery connection · Engine oil is too heavy · Load is connected
Fix: 1. Service the battery if necessary. 2. Clean and tighten battery connections. 3. Check the engine oil and, if too heavy, replace with recommended oil. 4. Disconnect the load before starting. - BLACK EXHAUST
Cause: · Choke stuck in the closed position · Dirty air cleaner · Rich fuel mixture
Fix: 1. Make sure the choke is open. 2. Clean the air cleaner.
Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan EGMBT (P4500).
Maintenance schedule
| Item | Spec | Capacity | Part # | Interval | |
|---|
| Air filter | Maintenance Schedule | | — | 1000 hr | find |
| Fuel filter | | | — | 500 hr | find |
| Oil filter | | | — | 1000 hr | find |
| Belt | | | — | 1000 hr | find |
| Coolant | | | — | 20 hr | |
| Coolant filter | | | — | | find |
| Oil | | 1.16 L | — | 100 hr | |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
Repair guides
73Step-by-step procedures compiled from the Cummins/Onan service manual for this engine.
Common questions
What is the oil capacity of the Cummins/Onan EGMBT (P4500)?
The Cummins/Onan EGMBT (P4500) engine has an oil capacity of 1.16 liters.
What is the displacement of the Cummins/Onan EGMBT (P4500)?
The Cummins/Onan EGMBT (P4500) has a displacement of 0.34 liters.
Which generators use the Cummins/Onan EGMBT (P4500) engine?
The Cummins/Onan EGMBT (P4500) powers 1 generator set(s), including Cummins/Onan EGMBT.
How often should you change the oil in the Cummins/Onan EGMBT (P4500)?
The Cummins/Onan EGMBT (P4500) oil change interval is every 100 hours.
What is a common problem with the Cummins/Onan EGMBT (P4500) engine?
A commonly reported issue on generators using the Cummins/Onan EGMBT (P4500) is: NO DC OUTPUT. Cause: · Tripped DC circuit breaker. Fix: 1. Disconnect the battery. 2. Reset the circuit breaker. 3. Have the battery tested for shorts and, if necessary, replace the battery..