The DC Logic System is a generator-set controller. It is used on generator sets from Northern Lights, including the M20C, M33, M673 and M843JK.
| Symptom | Cause | Remedy |
|---|---|---|
| Battery Will Not Charge | Loose or corroded connections | Clean and tighten battery connections. |
| Battery will not charge | Loose or corroded connections | Clean and tighten battery connections |
| Below Normal Engine Temperature | Thermostat not working properly | Check thermostat. |
| Engine Emits Black or Gray Exhaust Smoke | Clogged or dirty air cleaner | Service air cleaner. |
| Engine Emits White Smoke | Improper fuel | Use correct fuel for temperature. |
| Engine Hard to Start or Will Not Start | Improper starting procedure | See starting section of this manual. Take special note of Bypass Switch operation. |
| Engine Knocks | Insufficient oil | Call your dealer. |
| Engine Malfunctions at High Output Range | Fuel supply insufficient | Air in fuel system or clogged fuel filter element. |
| Engine Overheats | Low coolant level | Fill tank or radiator to proper level; Check hoses for loose connections and leaks. |
| Engine Runs Irregularly or Stalls Frequently | Below normal engine temperature | Remove and check thermostat. |
| Engine hard to start or will not start | Improper starting procedure | See starting section of this manual. Take special note of Bypass Switch operation |
| Engine runs irregularly or stalls frequently | Below normal engine temperature | Remove and check thermostat |
| Entire Electrical System Does Not Function | Check DC circuit breaker | If breaker is tripped, reset it. |
| Entire electrical system does not function | Check DC circuit breaker | If breaker is tripped, reset it |
| High Fuel Consumption | Improper type of fuel | Use correct fuel for temperature. |
| High Oil Consumption | Break-in period | Oil consumption decreases after break in. |
| Lack of Engine Power | Intake air restriction | Service air cleaner. |
| Lack of engine power | Engine overloaded | Reduce load |
| Low Oil Pressure | Low oil level | Fill crankcase to proper level. |
| Starter Cranks Slowly | Low battery output | Battery is too small; Battery cables are too small. |
| Starter Inoperative | Check DC circuit breaker | If the breaker is tripped, reset it. |
| Starter cranks slowly | Low battery output: Batteries too small; Battery cables too small | Check specific gravity of each battery; Replace battery if necessary |
| Starter inoperative | Check DC circuit breaker | If the breaker is tripped, reset it |