Home›Controllers›Computer Board (CCB)

Computer Board (CCB) Controller

The Computer Board (CCB) is a generator-set controller. It is used on generator sets from Generac, including the NP-30G.

1
Generator sets
Generac
Brand
Gasoline
Fuel

Generator sets using this controller

1

Engines paired with this controller

1

Troubleshooting

58

Fault codes

CodeMeaningRemedy
C1Low Oil Pressure ShutdownCheck the engine oil level.
C2High Temperature Shutdown
C4Low Voltage ShutdownDisconnect all loads the generator might power by whatever means provided, such as the recreational vehicle’s main circuit breaker.
M01Low Oil Pressure ShutdownCheck the engine oil level. If necessary, add oil to the FULL mark.
M02High Temperature Shutdown
M03Overspeed ShutdownDo not attempt a manual adjustment to control engine speed.
M04Low Voltage Shutdown
QAW WARNING
S1Overspeed ShutdownDo not attempt a manual adjustment to control the engine speed.
T1High Temperature Shutdown
V1Low Voltage Shutdown

Symptoms & remedies

SymptomCauseRemedy
AC output turns off intermittently. Then, engine runs at idle for 5 seconds. Finally, AC turns back on and unit runs normallyCCG board failureReplace CCG circuit board
AC voltage is available to the Wire 66 and 77 terminals at the Battery Charge Rectifier, but no voltage or a low voltage is measured between the BCR's Wire 55 terminal and groundThe Battery Charge Rectifier (BCR) is defective
AC voltage present at Wires 66 and 77 but DC voltage NOT present between Battery Charge Rectifier Wire 55 and frame groundBattery Charge Rectifier (BCR) is defectiveReplace Battery Charge Rectifier
AC voltage was present at the Wires 66 and 77 terminals of the Battery Charge Rectifier, but DC voltage is NOT present between the Battery Charge Rectifier's Wire 55 and frame groundThe Battery Charge Rectifier (BCR) is defective
AC voltage was present at the Wires 66 and 77 terminals, but DC voltage is NOT present between the Battery Charge Rectifier's Wire 55 and frame groundThe Battery Charge Rectifier (BCR) is defective
Battery charge winding resistance not within specification (Wires 66 to 55 = 0.037-0.042 Ohm; Wires 77 to 55 = 0.037-0.042 Ohm)Stator Assembly defectiveReplace Stator Assembly
Engine can be started, but shuts down after several secondsA timing detection failure may have occurred (Timing winding, Wires TIM1, TIM2)
Engine cranks but will not startLow fuel levelReplenish fuel supply
Engine cranks but won't startOut of fuelReplenish fuel
Engine does not accelerate when load is applied. After 10 seconds, engine shuts downCarburetor linkage sticking with throttle stuck closedRepair sticking throttle
Engine shutdown initiated by CCG boardOver-voltage
Engine shuts down but overspeed above 4500 rpm did not occurOne of four power windings in Stator is openRepair/replace bad wire(s) AC1/AC2 or SL1/SL2 or replace Stator
Engine speed and AC output voltage erratic under constant load. AC output does not turn off intermittentlyStepper Motor failureReplace Stepper Motor
Engine speed and output voltage are erratic under constant load, but the AC output does not turn off intermittentlyErratic timing detection may have occurred (Timing winding, Wires TIM1, TIM2)
Engine speed is maintained and no-load voltage is good. However, when load is applied output voltage drops and engine shuts downCarburetor linkage sticking with throttle partly openRepair sticking throttle
Engine starts but Stepper Motor does not move. Shut down occurs after several secondsPower Supply winding (PS1, PS2) is openRepair or replace bad wire(s) PS1/PS2 or replace Stator
Engine starts hard, runs rough, low full load powerAir cleaner plugged or damagedClean or replace as needed
Engine starts, accelerates, shuts down at 4500 rpmCarburetor linkage sticking with throttle stuck openRepair sticking throttle
Engine starts, but Stepper Motor does not move, and engine shuts down after several secondsCCG circuit board's micro-controller may not be operating
Engine starts, but Stepper Motor does not move. Engine appears to operate too slowly; Engine is not able to handle the load and unit operates at low AC output voltage; After several seconds under load, AC output voltage is turned off (overload condition)A failure of the circuit board's Stepper Motor drive
Engine starts, but Stepper Motor does not move. Engine appears to operate too slowly; engine is not able to handle the load and unit operates at low AC output voltage; after several seconds under load, AC output voltage is turned off (overload condition)Failure of the circuit board's Stepper Motor drive
Engine starts, but Stepper Motor does not move. The engine accelerates uncontrollably and shuts down when engine speed exceeds 4500 rpmA failure of the circuit board's Stepper Motor drive
Engine starts, but the Stepper Motor does not move, and engine shuts down after several secondsThe CCG circuit board's micro-controller may not be operating
Engine starts, but then shuts down after startupA problem could exist in either the generator computer system or in the engine DC control systemIsolate the CCG system using the test fixture; if the engine starts and shuts down, check engine oil level (if oil level is low, replenish as necessary; if oil level is NOT low, go to Test 26); if engine was shutting down after startup, but does not shut down during this test, the problem is in the CCG system, go to Test 27
Engine starts, shuts down when Start/Stop switch is releasedEngine oil is lowCheck oil; add as needed
Engine will not crank15 amp fuse badReplace bad fuse
Engine will not start (spark plug DRY)Carburetor gasket(s) leakingAdjust or repair carburetor or fuel system as necessary
Engine will not start (spark plug WET)OverchokingAdjust or repair carburetor or fuel system as necessary
Engine will not start or starts hard and runs roughA failure in the engine's mechanical systemPerform a compression check; if compression is poor, look for one or more of the following possible causes: Loose cylinder head bolts; Failed cylinder head gasket; Burned valves or valve seals; Insufficient valve clearance; Warped cylinder head; Warped valve stem; Worn or broken piston ring(s); Worn or damaged cylinder bore; Broken connecting rod
Engine will not start or starts hard and runs rough (poor compression)Loose cylinder head bolts
Engine will not start, spark plug is DRYCarburetor gasket(s) leaking; Fuel line plugged or shutoff valve not opening; Intake valve stuck closed; Inoperative fuel pump; Clogged fuel filterAdjust or repair carburetor or fuel system as necessary
Engine will not start, spark plug is WETOverchoking; Water in fuel; Excessively rich fuel mixture; Intake valve stuck openAdjust or repair carburetor or fuel system as necessary
Engine won't crank15 amp fuse is blownReplace 15 amp fuse
Engine won't start or starts hard and runs roughCarburetionMake sure the fuel tank has an ample supply of clean fresh gasoline (gasoline fuel systems) or gaseous fuel; make sure all shutoff valves are open; adjust the carburetor as outlined on Page 3.4-2; make sure the automatic choke is working properly and that the choke closes completely; adjust or repair carburetor or fuel system as necessary
Genistor fails resistance/continuity testsGenistor defectiveReplace Genistor
No AC voltage can be measured across Stator connections at the Battery Charge Rectifier (BCR)An open circuit condition probably exists in Wire 66 (Brown), or Wire 77 (Brown)
No AC voltage is measured at the Wires 66 and 77 terminals of the Battery Charge Rectifier, with the unit runningAn open circuit exists in the wire 66 or 77 circuit
No AC voltage measured at Wires 66 and 77 terminals of the Battery Charge Rectifier with unit runningOpen circuit exists in the wire 66 or 77 circuit
Overvoltage condition and speed control system cannot reduce output voltageCarburetor linkage sticking with throttle stuck partly openRepair sticking throttle
Premature high temperature shutdownsSome early production units were equipped with a 265° F. switchThe 265° F. switch should be removed and replaced with the Part No. 94090 switch
Priming function does not work15 amp fuse is badReplace bad fuse
Problem in AC generator system when other components tested goodCCG circuit boardReplace the CCG circuit board and check unit operation
Start/Stop switch at Stop, engine continues to runDefective Start/Stop switchReplace switch
The engine can be started, but shuts down after several secondsA timing detection failure may have occured (Timing winding, Wires TIM1, TIM2)
The engine speed and output voltage are erratic under constant load, but the AC output does not turn off intermittentlyErratic timing detection may have occured (Timing winding, Wires TIM1, TIM2)
The engine starts, but the Stepper Motor does not move, and engine shuts down after several secondsThe CCG circuit board's micro-controller may not be operating
Under heavy load, output turns off and engine speed drops to idleCCG circuit board failureReplace CCG circuit board

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.