Home TroubleshootingMagnum MMG45K

Magnum MMG45K Troubleshooting

Magnum MMG45K troubleshooting: 8 fault codes and symptom-cause-remedy entries from the manufacturer's own service documentation.

Magnum MMG45K — full specs, parts & maintenance.

Troubleshooting

8

Fault codes

CodeMeaning
FCECU alarm FailureCode
nullThe door covering the customer connection lugs/cam lock receptacles is opened.

Symptoms & remedies

SymptomCauseRemedy
LOW FUEL LEVEL SHUT DOWNFuel level is low or fuel tank has leaks.Check the fuel level on the LCD window. Ensure no leaks in the fuel tank. Check the fuel level sender and connecting wiring for damage.
LOW OIL PRESSURE SHUT DOWNOil pressure is less than 20 psi (138 kPa).Check the engine oil level with a dipstick. Visually inspect for oil leaks. If oil level is good, restart and verify oil pressure within five seconds. Check the oil pressure sender.
LOW COOLANT LEVEL SHUT DOWNCoolant level in the radiator is low.Allow engine to cool. Check coolant level in the radiator. Access the radiator cap by removing the access panel from the top of the enclosure.
High Coolant Temperature Shut downCheck the coolant level in the overflow jug. Restart the engine and read the coolant temperature to verify High Coolant Temperature Shut down. Stop the engine immediately if the coolant temperature is 230°F (110°C) or more. Allow the engine to cool. Add coolant to the overflow jug if it is low and then check the level of coolant in the radiator. To access the radiator cap, you must remove the access panel from the top of the enclosure directly above the radiator. Add coolant until it is 3/4” below the filler neck. Secure the radiator cap back into its original position. Check the radiator shroud and ducting for blockage and remove any foreign matter. Inspect coolant hoses, engine block and water pump for visible leaks.
Overcrank Shut downCheck the fuel level in the tank. Check for proper operation of the fuel pump. Check air filter for blockage. If the engine will not start, consult the engine operation and maintenance manual for additional information on troubleshooting starting problems.
Overspeed or Underspeed Shut downDisconnect all loads and restart the generator. Read the frequency (Hz) on the LCD display. With no loads on the generator, the frequency should read 60.0 Hz. If the frequency is above or below 60.0 Hz, the engine speed will have to be adjusted. See the engine manual for throttle adjustments on mechanically governed units and see the electronic governor manual for electronically controlled units.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Common questions

Magnum MMG45K: LOW FUEL LEVEL SHUT DOWN — what causes it?

Documented causes: Fuel level is low or fuel tank has leaks.. See the table for the matching fixes.

Magnum MMG45K: LOW OIL PRESSURE SHUT DOWN — what causes it?

Documented causes: Oil pressure is less than 20 psi (138 kPa).. See the table for the matching fixes.

Magnum MMG45K: LOW COOLANT LEVEL SHUT DOWN — what causes it?

Documented causes: Coolant level in the radiator is low.. See the table for the matching fixes.