| Symptom | Cause | Remedy |
|---|---|---|
| Mast Lights OFF but ballast indicators on control panel ON | Light fixture too hot | Allow light fixture to cool 10-15 minutes before restarting. |
| Mast Lights OFF and ballast indicators on control panel OFF | Lighting connections loose | Check wire connections: • Inside control box • Inside each ballast box |
| Generator output incorrect | Check voltage to ballasts by checking voltage to the GFCI outlet. Correct incoming voltage is 120 V, ±5 V. If voltage is incorrect, engine speed may need to be adjusted, or generator may require service. | |
| Transformer output low | Verify voltage from transformer: When a bulb strikes (induces an arc), transformer voltage should be approximately 400 VAC. Next, voltage should drop, slowly rise, then stabilize at 240–260 VAC. On hard-wired models, remove mast junction box cover and insert wire probes into the connector blocks of the light and ground. If correct voltage is not achieved, check the capacitor to determine if capacitor or coil must be replaced. | |
| Mast Lights ON but light output low | Fixture and/or lens is dirty | Clean components: • Reflective surface of light fixture • Inside and outside surface of glass lens IMPORTANT NOTE: Clean components only with mild soap and water. Other chemicals may damage surfaces and glass. |
| Electrical connections damaged or loose | Check: • Mast coil cord • Mast junction box • Mast light connections | |
| Low transformer output | Verify voltage from transformer: When a bulb strikes (induces an arc), transformer voltage should be approximately 400 VAC. Next, voltage should drop, slowly rise, then stabilize at 240–260 VAC. On hard-wired models, remove mast junction box cover and insert wire probes into the connector blocks of the light and ground. If correct voltage is not achieved, check the capacitor to determine if capacitor or coil must be replaced. | |
| Mast lights off, checking outside control box | Light fixture too hot | Allow light fixture to cool 10–15 minutes before restarting. |
| Fuel filter faulty | With engine running and lights off, measure voltage and frequency at the GFCI receptacle. Voltage should indicate 120VAC ± 5%, and frequency should indicate 60.7 Hz ± 5%. If frequency and voltage are both low (<114VAC, <58 Hz), replace the fuel filter. | |
| Generator capacitor faulty | Measure the capacitance of the generator capacitor. If measurement is outside rating (as indicated on the capacitor), replace the capacitor. | |
| Mast lights off, checking inside control box | Lighting connections loose | Check connections inside control box. |
| Low oil pressure shutdown | Low oil level | Verify oil level on dipstick. Add oil, if needed. |
| Oil leaking from engine | Visually inspect the engine for leaks. | |
| Oil pressure switch failure | Refer to OEM engine operator’s manual to identify corrective action. | |
| High coolant temperature shutdown | Low coolant level | Add coolant if needed. Allow engine to cool, then check coolant level in radiator. Restart engine and check coolant temperature. Stop engine immediately if coolant temperature is 210°F (99°C) or more. |
| Blockage in radiator | Inspect radiator shroud and ducting for blockage and remove any foreign matter. | |
| Leakage in coolant hoses, engine block, or water pump | Inspect for visible leaks. Verify tension of water pump serpentine drive belt. | |
| Unit cranks but does not start | Fuel level low | Check fuel level in tank. Verify fuel pump operation. |
| Restricted air filter | Inspect air filter for blockage. Refer to OEM engine operator’s manual for additional information |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Documented causes: Light fixture too hot. See the table for the matching fixes.
Documented causes: Lighting connections loose. See the table for the matching fixes.
Documented causes: Fixture and/or lens is dirty. See the table for the matching fixes.