Low oil pressure shutdownLow oil levelVerify oil level on dipstick. Add oil, if needed.
Low oil pressure shutdownOil leaking from engineVisually inspect the engine for leaks.
Low oil pressure shutdownOil pressure switch failureRefer to OEM engine operator's manual to identify corrective action.
High coolant temperature shutdownLow coolant levelAdd coolant if needed. Allow engine to cool, then check coolant level in radiator. Restart engine and check coolant temperature. Stop engine immediately if coolant temperature is 210°F (99°C) or more.
High coolant temperature shutdownBlockage in radiatorInspect radiator shroud and ducting for blockage and remove any foreign matter.
High coolant temperature shutdownLeakage in coolant hoses, engine block, or water pumpInspect for visible leaks. Verify tension of water pump serpentine drive belt. Remove load on generator and restart engine. Verify coolant temperature and shut engine down immediately if it starts to overheat. Refer to the OEM engine operator's manual for additional information on engine overheating.
Unit cranks but does not startFuel level lowCheck fuel level in tank. Verify fuel pump operation.
Unit cranks but does not startRestricted air filterInspect air filter for blockage. Refer to OEM engine operator's manual for additional information.
Mast Lights OFF but ballast indicators on control panel ONLight fixture too hotAllow light fixture to cool 10-15 minutes before restarting.
Mast Lights OFF but ballast indicators on control panel ONBulb connection faultyEnsure bulb is securely installed to socket.
Mast Lights OFF but ballast indicators on control panel ONBulb brokenCheck for: Broken arc tube or outer lamp jacket; Broken or loose components in lamp envelope; Blackening/deposits inside tube.
Mast Lights OFF but ballast indicators on control panel ONLighting connections looseCheck wire connections: Inside mast junction box; Bulb housings and sockets.
Mast Lights OFF but ballast indicators on control panel ONElectrical cord damaged or looseCheck: Mast electrical cord for damage; Cord connections inside control box.
Mast Lights OFF and ballast indicators on control panel OFFLighting connections looseCheck wire connections: Inside control box; Inside each ballast box.
Mast Lights OFF and ballast indicators on control panel OFFGenerator output incorrectCheck voltage to ballasts by checking voltage to the GFCI outlet. Correct incoming voltage is 120 V, ±5 V. If voltage is incorrect, engine speed may need to be adjusted, or generator may require service. Before adjusting engine speed, change fuel filter.
Mast Lights OFF and ballast indicators on control panel OFFTransformer output lowVerify voltage from transformer: When a bulb "strikes" (induces an arc), transformer voltage should be approximately 400 VAC. Next, voltage should drop, slowly rise, then stabilize at 240–260 VAC. On hard-wired models, remove mast junction box cover and insert wire probes into the connector blocks of the light and ground. If correct voltage is not achieved, check the capacitor to determine if capacitor or coil must be replaced.
Mast Lights ON but light output lowFixture and/or lens is dirtyClean components: Reflective surface of light fixture; Inside and outside surface of glass lens. Clean components only with mild soap and water. Other chemicals may damage surfaces and glass.
Mast Lights ON but light output lowBulb worn, due to normal useReplace bulb.
Mast Lights ON but light output lowElectrical connections damaged or looseCheck: Mast coil cord; Mast junction box; Mast light connections.
Mast Lights ON but light output lowGenerator output incorrectCheck voltage to ballasts by checking voltage to the GFCI outlet. Correct incoming voltage is 120 V, ±5 V. If voltage is incorrect, engine speed may need to be adjusted, or generator may require service. Before adjusting engine speed, change fuel filter.
Mast Lights ON but light output lowLow transformer outputVerify voltage from transformer: When a bulb strikes (induces an arc), transformer voltage should be approximately 400 VAC. Next, voltage should drop, slowly rise, then stabilize at 240–260 VAC. On hard-wired models, remove mast junction box cover and insert wire probes into the connector blocks of the light and ground. If correct voltage is not achieved, check the capacitor to determine if capacitor or coil must be replaced.
Mast lights off, checking outside control boxLight fixture too hotAllow light fixture to cool 10–15 minutes before restarting.
Mast lights off, checking outside control boxLighting connections looseCheck wire connections: Inside mast junction box; LED housings and sockets.
Mast lights off, checking outside control boxElectrical cord damaged or looseCheck: Mast electrical cord for damage; Cord connections inside control box.
Mast lights off, checking outside control boxFuel filter faultyWith engine running and lights off, measure voltage and frequency at the GFCI receptacle. Voltage should indicate 120VAC ± 5%, and frequency should indicate 60.7 Hz ± 5%. If frequency and voltage are both low (<114VAC, <58 Hz), replace the fuel filter.
Mast lights off, checking outside control boxGenerator capacitor faultyMeasure the capacitance of the generator capacitor. If measurement is outside rating (as indicated on the capacitor), replace the capacitor.
Mast lights off, checking inside control boxLighting connections looseCheck connections inside control box.
Mast lights off, checking inside control boxGenerator output incorrectCheck voltage to ballast drivers by checking voltage to the GFCI receptacle. Correct incoming voltage is 120 V, ±5 V. If voltage is incorrect, the generator may require service. Before adjusting engine speed, change fuel filter.
Unit cranks, but will not startFuel level lowCheck fuel level in tank. Verify fuel pump operation.
Unit cranks, but will not startRestricted air filterInspect air filter for blockage. Refer to OEM engine operator's manual for additional information.
Mast lights OFF, ballast indicators ONLight fixture is too hotAllow light to cool 10-15 minutes before restarting.
Mast lights OFF, ballast indicators ONFaulty lamp connectionCheck that the lamp is tight in the socket.
Mast lights OFF, ballast indicators ONLamp brokenCheck for broken arc tube or outer lamp jacket, broken or loose components in lamp envelope, or blackening/deposits inside tube.
Mast lights OFF, ballast indicators ONLoose lighting connectionsCheck the connections inside the mast junction box and each mast light housing/socket.
Mast lights OFF, ballast indicators ONDamaged or loose electrical cordCheck the mast electrical cord for damage and check the cord connections inside the control box.
Mast lights OFF, ballast indicators OFFLoose lighting connectionsCheck the connections inside the control box and inside each ballast box.
Mast lights OFF, ballast indicators OFFGenerator output incorrectCheck the incoming voltage to the ballast by checking the available voltage on the GFCI receptacle. Incoming voltage should be 120V ±5V. If voltage is incorrect, the engine speed may need to be adjusted or generator may require service.
Mast lights OFF, ballast indicators OFFLow transformer outputThe voltage from the transformer should read approximately 400VAC as the light "strikes" (induces an arc), then drop and slowly rise back up to stabilize at 240-260VAC. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced.
Mast lights ON, low light outputFixture and/or lens is dirtyClean reflective surface inside fixture and both inside and outside surface of glass lens. Use mild soap and water to clean lens. Other chemicals may have an adverse effect on the glass.
Mast lights ON, low light outputLamp worn due to normal useReplace lamp.
Mast lights ON, low light outputDamaged or loose electrical connectionsCheck the mast coil cord, mast junction box and mast light connections.
Mast lights ON, low light outputGenerator output incorrectCheck the incoming voltage to the ballast.
Mast lights ON, low light outputLow transformer output
Overspeed or Underspeed ShutdownFrequency setting incorrectDisconnect all loads and restart unit. Read frequency (Hz) in the LCD window on controller. Frequency should read 60 Hz. If frequency is above 60 Hz, engine speed will need to be adjusted. Refer to the engine operator's manual for throttle adjustment information.
Mast Lights Off, but Ballast Indicators on Control Panel are On.Light fixture is too hot.Allow light to cool 10-15 minutes before restarting.
Mast Lights Off, but Ballast Indicators on Control Panel are On.Faulty lamp connection.Check that the lamp is tight in the socket.
Mast Lights Off, but Ballast Indicators on Control Panel are On.Lamp brokenCheck for broken arc tube or outer lamp jacket, broken or loose components in lamp envelope, or blackening/deposits inside tube.
Mast Lights Off, but Ballast Indicators on Control Panel are On.Loose lighting connectionsCheck the connections inside the mast junction box and each mast light housing/socket.
Mast Lights Off, but Ballast Indicators on Control Panel are On.Damaged or loose electrical cordCheck the mast electrical cord for damage and check the cord connections inside the control box.
Mast Lights Off, and Ballast Indicators on the Control Panel are Off.Loose lighting connectionsCheck the connections inside the control box and inside each ballast box.
Mast Lights Off, and Ballast Indicators on the Control Panel are Off.Generator output incorrect.Check the incoming voltage to the ballast by checking the available voltage on the GFCI receptacle. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, the engine speed may need to be adjusted or generator may require service.
Mast Lights Off, and Ballast Indicators on the Control Panel are Off.Low transformer output.The voltage from the transformer should read approximately 400VAC as the light "strikes" (induces an arc), then drop and slowly rise back up to stabilize at 240-260VAC. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced.
Mast Lights On But the Light Output is LowFixture and/or lens is dirty.Clean reflective surface inside fixture and both inside and outside surface of glass lens. Use mild soap and water to clean lens. Other chemicals may have an adverse effect on the glass.
Mast Lights On But the Light Output is LowLamp worn due to normal useReplace lamp.
Mast Lights On But the Light Output is LowDamaged or loose electrical connectionsCheck the mast coil cord, mast junction box and mast light connections.
Mast Lights On But the Light Output is LowGenerator output incorrect.Check the incoming voltage to the ballast. Incoming voltage should be 120V +/-5V. If the voltage is incorrect, the engine speed may need to be adjusted or the generator may require service.
Mast Lights On But the Light Output is LowLow transformer outputThe voltage from the transformer should read approximately 400VAC as the light "strikes" (induces an arc), then drop and slowly rise back up to stabilize at 240-260VAC. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Common questions

Generac MLT4060: Mast Lights OFF but ballast indicators on control panel ON — what causes it?

Documented causes: Light fixture too hot; Bulb connection faulty; Bulb broken; Lighting connections loose. See the table for the matching fixes.

Generac MLT4060: Mast Lights ON but light output low — what causes it?

Documented causes: Fixture and/or lens is dirty; Bulb worn, due to normal use; Electrical connections damaged or loose; Generator output incorrect. See the table for the matching fixes.

Generac MLT4060: Mast lights off, checking outside control box — what causes it?

Documented causes: Light fixture too hot; Lighting connections loose; Electrical cord damaged or loose; Fuel filter faulty. See the table for the matching fixes.