Generac 9344 troubleshooting: 23 fault codes and symptom-cause-remedy entries from the manufacturer's own service documentation.
Generac 9344 — full specs, parts & maintenance.
| Code | Meaning |
|---|---|
| EST 1 | Ac OUTPUT VOLTAGE |
| TEST 2 | VOLTAGE REGULATOR LAMPS |
| TEST 3 | REPLACE VOLTAGE REGULATOR |
| TEST 4 | TEST EXCITATION CIRCUIT BREAKER |
| TEST 5 | TEST EXCITATION WINDING |
| TEST 6 | TEST THERMAL PROTECTOR |
| TEST 7 | TEST EXCITATION LEADS |
| TEST 8 | REGULATOR TEST & ADJUST |
| TEST 9 | CHECK SENSING LEADS TRANSFORMER POWER WINDINGS |
| TEST 10 | STATOR AC GOOD |
| TEST 11 | TEST Rotor Brushes AND Wires No. 1 & 4 BOOST |
| TEST 12 | CHECK FIELD |
| TEST 13 | CHECK SLIP RINGS 1 AND 4 |
| TEST 14 | RECONNECT, REPAIR OR REPLACE BAD WIRE(S) OR PART(S) |
| TEST 15 | CHECK BOTH VOLTAGE AND FREQUENCY |
| TEST 16 | ADJUST ENGINE GOVERNOR |
| TEST 17 | CHECK VOLTAGE REGULATOR |
| TEST 18 | UNIT IS NOT OVERLOADED |
| TEST 19 | REPAIR ENGINE POWER |
| OC | Field boost voltage is available. |
| Symptom | Cause | Remedy |
|---|---|---|
| Engine won't crank. | 10 amp circuit breaker trioped.<br>14 amp fuse blown.<br>Loose, corroded or defective battery cables.<br>Defective engine Start/Stop switch.<br>Defective starter contactor.<br>Defective starter motor. | 1. Reset circuit breaker<br>2. Replace fuse.<br>3. Tighten, clean or replace battery cables as necessary.<br>4. Replace Start/Stop switch.<br>5. Replace contactor.<br>6. Replace starter motor. |
| Engine cranks but won't start. | Vehicle fuel shutoff valve is closed.<br>Out of fuel.<br>Fuel soienoid (FS) is defectcive<br>Fuel pump (FP) is defective.<br>Open Wire #14 from Engine Control C.B.<br>Clogged fuel filter or fuel line.<br>Engine mechanical parts failure.<br>Spark plugs defective. | 1. Open valve.<br>2. Replenish fuel tank.<br>3. Refplace solenoid.<br>4. Repair or replace fuel pump.<br>5. Reconnect wire.<br>6. Replace if clogged.<br>7. Repair or replace parts.<br>8. Clean, regap or replace plugs. |
| Engine starts hard, runs rough. | Flame arrestor (air |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Documented causes: 10 amp circuit breaker trioped.<br>14 amp fuse blown.<br>Loose, corroded or defective battery cables.<br>Defective engine Start/Stop switch.<br>Defective starter contactor.<br>Defective starter motor.. See the table for the matching fixes.
Documented causes: Vehicle fuel shutoff valve is closed.<br>Out of fuel.<br>Fuel soienoid (FS) is defectcive<br>Fuel pump (FP) is defective.<br>Open Wire #14 from Engine Control C.B.<br>Clogged fuel filter or fuel line.<br>Engine mechanical parts failure.<br>Spark plugs defective.. See the table for the matching fixes.
Documented causes: Flame arrestor (air. See the table for the matching fixes.