Home›Repair guides›Westinghouse›Storing the Generator

Westinghouse WGen9500 — Storing the Generator

Maintenance

For the Westinghouse WGen9500, from the Westinghouse owner's manual.

Applies to: Westinghouse WGen9500

Before you start

  • Gasoline stored 60+ days can go bad, causing gum/varnish/corrosive buildup

Procedure

  1. Switch Engine Switch to STOP so generator doesn't draw battery power
  2. Clean the generator
  3. Drain all gasoline from fuel tank as best as possible
  4. With fuel shutoff valve open, run engine until remaining gasoline is consumed and engine shuts off
  5. Close fuel shutoff valve
  6. Drain remaining gas in carburetor float bowl
  7. Change the oil
  8. Remove spark plug, add about 1 tablespoon of oil into opening, pull recoil handle several times
  9. Replace the spark plug
  10. Move generator to clean, dry storage location

Full service-parts list: Westinghouse WGen9500 →

Source: Westinghouse owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.