Home›Repair guides›Westinghouse›Checking and Adjusting Valve Lash

Westinghouse WGen9500 — Checking and Adjusting Valve Lash

Adjustments · Valve Train

For the Westinghouse WGen9500, from the Westinghouse owner's manual.

Applies to: Westinghouse WGen9500

Before you start

  • Must be performed with engine cold

Procedure

  1. Remove rocker arm cover and gasket (replace if torn)
  2. Remove spark plug to allow engine rotation
  3. Rotate engine to TDC of compression stroke
  4. Confirm both rocker arms loose at TDC; rotate 360 deg if not
  5. Insert feeler gauge between rocker arm and push rod, check clearance per Table 3
  6. If adjustment required, hold adjusting nut and loosen jam nut
  7. Turn adjusting nut to obtain correct valve lash
  8. Tighten jam nut to 106 in-lb (12 N-m) while holding adjusting nut
  9. Recheck valve lash after tightening jam nut
  10. Repeat for both intake and exhaust valves
  11. Install rocker arm cover, gasket, and spark plug

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Intake 0.0035+/-0.0043 in cold; Exhaust 0.0043+/-0.0051 in cold; jam nut 106 in-lb (12 N-m)

Full service-parts list: Westinghouse WGen9500 →

Source: Westinghouse owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Westinghouse repair guides →