Westinghouse — Quick Drain
Maintenance · fuel system
From a Westinghouse owner's manual covering: 10KPRO, 8KPRO, WH10KPRO, WH8KPRO. Check it applies to your exact model before use.
Applies to: Westinghouse 10KPRO
Before you start
- Gasoline vapors extremely flammable, wipe up spills immediately
Procedure
- Remove drain hose cap from drain hose
- Open quick drain valve, drain fuel into container
- Continue draining until clean fuel observed
- Close quick drain valve, install drain hose cap
- Dispose of collected fuel properly
Full service-parts list: Westinghouse 10KPRO →