Home›Repair guides›Wacker Neuson›Replacing the Aftertreatment DEF Dosing Unit Filter

Wacker Neuson G 25 — Replacing the Aftertreatment DEF Dosing Unit Filter

Maintenance

For the Wacker Neuson G 25, from the Wacker Neuson owner's manual.

Applies to: Wacker Neuson G 25

Before you start

  • DEF contains urea. Do not get in eyes.
  • Do not disconnect the DEF line while under low pressure.

Procedure

  1. Remove the filter cap.
  2. Remove the filter equalizing element.
  3. Use the disposable filter tool to remove the filter element.
  4. Clean the filter cap and threads with warm water and a clean cloth.
  5. Insert the equalizing element into the new filter.
  6. Insert the filter assembly into the aftertreatment dosing unit.
  7. Re-install the filter cap and torque to 20 Nm (14.8 ft.lbs.).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Torque filter cap to 20 Nm (14.8 ft.lbs.)

Source: Wacker Neuson owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.